Docsity
Docsity

Prepare for your exams
Prepare for your exams

Study with the several resources on Docsity


Earn points to download
Earn points to download

Earn points by helping other students or get them with a premium plan


Guidelines and tips
Guidelines and tips

2gig cheat sheet, Cheat Sheet of Computer Security

Great and complete 2gig cheat sheet

Typology: Cheat Sheet

2018/2019

Uploaded on 09/02/2019

sumaira
sumaira 🇺🇸

4.7

(51)

21 documents

Partial preview of the text

Download 2gig cheat sheet and more Cheat Sheet Computer Security in PDF only on Docsity! QUICK PROGRAMING GUIDE page1 Connect the battery and power up the system select: SECURITY, MENU, TOOLBOX, RIGHT ARROW, INSTALLER TOOLBOX enter: 1561 select: Here is where you will be programing your different zones, or modifying the field programing. (see your Instalation/Programing Guide) System Configuration Q.1 ZONE PROGRAMING Scroll between options using Move to previous or next prompt by selecting or Q.1 RF SENSOR PROGRAMING (1 thru 48) select: Sensor (zone) Type (see p.2) select: Equipment Code (see p.2) enter: Serial Number Enter the serial number manually or Learn in the sensor by selecting: Shift, Learn, then trip the sensor select: Equipment Age (New/Existing) select: Sensor Loop Number Loop 1-Motions, Glassbreaks, Smoke, Recessed D/W, Panic Pendant, D/W with wire lead Loop 2-D/W using internal switch Loop 3-Flood and Freeze Sensors select: Dialer Delay (Enabled/Disabled) select: Voice Descriptor (see p.2) Insert to add a word, then type the 3 digit code Repeat for additional words and to move between words select: Sensor Reports (Enabled/Disabled) select: Sensor Supervised (Enabled/Disabled) select: Sensor Chine 0-Disabled 1-Voice Only 2-Voice with Ding-Dong 3-Loud Ding-Dong 4-Loud Ding-Dong with Voice 5-Ding-Dong SUMMARY SCREEN Look over sensor information to make sure all settings are satisfactory. Edit Next to add the next sensor Skip to move to Wired Sensor programing (Q:02) Skip (again) to move to Keyfob programing (Q:03) Q.2 WIRED SENSOR PROGRAMING (1-2) select: Sensor (Zone) Type (see p.2) select: Equipment Code (see p.2) select: Equipment Age (New/Existing) select: Normal State 0-Not Used 1-Normaly Closed 3-Normaly Open 4-Mixed with no EOL select: Dialer Delay (Enabled/Disabled) select: Voice Descriptor (same as RF sensor programing. See p.2) select: Sensor Reports (Enabled/Disabled) select: Sensor Chimes (same as RF sensor programing) SUMMARY SCREEN Look over sensor information to make sure all settings are satisfactory. Edit Next to add the next wired sensor Skip to move to keyfob programming (Q:03) Skip (again) to move to keypad programming (Q:04) or or or or or or or or or ///////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////// ///////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////// /////////////////////////////////////////////////////////////////////////// /////////////////////////////////////////////////////////////////////////// /////////////////////////////////////////////////////////////////////////// /////////////////////////////////////////////////////////////////////////// /////////////////////////////////////////////////////////////////////////// Q.3 KEYFOB PROGRAMING Q.3 FOB # (1 thru 8) select: Fob Used (Used/Unused) select: Equipment Code (see p.2) enter: Serial Number (Same as RF Programing) select: Equipment Age (New/Existing) select: Emergency Key 0-Disabled 1-Auxilary 2-Audible 3-Silent Panic 4-Fire select: Fob Can Disarm (Enabled/Disabled) select: Voice Descriptor (Same as RF Programing. See p.2) select: Fob Arm with No Delay (Enabled/Disabled) select: Fob Output 0-Disabled 1-Toggle Output 2-Momentary Output SUMMARY SCREEN Look over sensor information to make sure all settings are satisfactory. Edit Next to add the next keyfob Skip to move to keypad programming (Q:04) Skip (again) to move to exit/entry time (Q:05) Q.4 KEYPAD PROGRAMING Q.4 KEYPAD # (1 thru 4) select: Keypad Used (Used/Unused) select: Equipment Code (see p.2) enter: Serial Number (Same as RF Programing) select: Equipment Age (New/Existing) select: Emergency Key (Enabled/Disabled) select: Voice Descriptor (Same as RF Programing. See p.2) SUMMARY SCREEN Look over sensor information to make sure all settings are satisfactory. Edit Next to add the next keypad Skip to move to exit/entry delay time (Q:05) FIELD PROGRAMING 2GIG TECH SUPPORT 855.2GIG.TECH (855.244.4832) EXITING SYSTEM CONFIGURATION Change the Que When at the top of a Question (ex: Q1:Select RF sensor # (01-48)) press: end Press: exit (make sure the box IS checked in the “save changes” box) the system will perform a system reboot to implement the changes. stions below accordingly: 2-WAY or DIGITAL Go To: 13- enter 1 (2-way) enter 0 (digital) CELL BACKUP or POTS PRIMARY Go To: 08-Enable Go To: 63-Enable Go To: 11-Enter Receiver Line# Go To: 12-Enter CSID# QUICK PROGRAMING GUIDE page2 ///////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////// ///////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////// ZONE TYPES VOICE DESCRIPTORS [01] ENTRY/EXIT1 (DOORS) [02] ENTRY/EXIT 2 (DOORS BY CUST REQUEST [03] PERIMETER (WINDOWS/GLASSBREAK) [04] INTERIOR FOLLOWER (MOTION) [05] TROUBLE DAY/ALARM NIGHT [06] 24 HR SILENT [07] 24 HR AUDIBLE (POLICE) [08] 24 AUX (MEDICAL, PANIC, FREEZE, H2O) [09] FIRE/HEAT WITHOUT VERIFY (SMOKE/HEAT) [10] INTERIOR WITH DELAY (MOTION) [14] CARBON MONOXIDE (CO DETECTOR) [16] FIRE WITH VERIFICATION [23] NO RESPONSE [24] SILENT BURGLARY EQUIPMENT CODES 0000 - OTHER 0862 - DW10-345 THIN D/W (SURFACE) CONTACT 0863 - DW20-345 RECESSED DOOR CONTACT 0869 - PIR-345 MOTION WITH PET IMMUNITY 0864 - GB1-345 GLASS BREAK DETECTOR 0872 - SMKE1-345 SMOKE DETECTOR (USA) 0871 - SMK1-345C SMOKE DETECTOR (CANADA) 0868 - PANIC1-345 PANIC BUTTON REMOTE 0860 - CO1-345 CO DETECTOR (USA) 0859 - CO1-345C CO DETECTOR (CANADA) 0873 - TAKE-345 TAKEOVER MODULE 0866 - KEY1-345 KEYFOB 0867 - PAD1-345 KEYPAD 0637 - HONEYWELL D/W “5816” 0470 - HONEYWELL R-D/W “5818MNL” 0533 - HONEYWELL PIR “5890” 0530 - HONEYWELL PIR “5894PI” 0519 - HONEYWELL GLASS BREAK “5853” 0589 - HONEYWELL SMOKE “5008W3” 0557 - HONEYWELL HEAT SENSOR “5809” 0624 - HONEYWELL FLOOD SENSOR “5821” 0491 - HONEYWELL PANIC PENDANT “5802MN2” 002 ABORT 003 ac 004 access 005 alarm 006 and 007 announcement 008 area 009 arm 010 armed 011 arming 012 at 013 attic 014 audio 015 auto 016 automation 017 auxiliary 018 away 019 BABYS 020 back 021 basement 022 bathroom 023 battery 024 bedroom 025 bonus 026 break 027 button 028 bypass 029 bypassed 030 CABINET 031 cancel 032 carbon monoxide 033 cellar 034 cellular 035 cell radio 036 center 037 check 038 chest 039 childrens 040 chime 041 closet 042 code 043 communications 044 computer 045 control 046 cool 047 crawl 048 current 049 DAY 050 degrees 051 den 052 detector 053 dim 054 dining 055 disarm 056 disarmed 057 dock 058 door 059 downstairs 060 driveway 061 EAST 062 eight 063 eighteen 064 eighty 065 electric 066 eleven 067 emergency 068 enter 069 entrance 070 entry 071 error 072 exercise 073 exit 074 exit now 075 exterior 076 external 077 FAILURE 078 family 079 fan 080 !fteen 081 !fty 082 !re 083 !re alert 084 !re detector 085 !rst 086 !ve 087 "ood 088 "oor 089 "uid 090 foil 091 for 092 forty 093 four 094 fourteen 095 fourth 096 freeze 097 freezer 098 front 099 furnace 100 GAME 101 garage 102 gas 103 glass 104 glassbreak 105 guest 106 gun 107 HALL 108 hallway 109 hanging 110 hang up 111 heat 112 high 113 home 114 house 115 ICE 116 inside 117 instant 118 interior 119 intrusion 120 is 121 KEY 122 keyfob 123 keypad 124 kids 125 kitchen 126 LAUNDRY 127 left 128 level 129 library 130 light 131 lights 132 liquor 133 living 134 loading 135 lock 136 loft 137 low 138 MAIN 139 maintenance 140 master 141 medical 142 medicine 143 menu 144 middle 145 monitor 146 motion 147 motion detector 148 mud 149 NINE 150 nineteen 151 ninety 152 north 153 not 154 not ready 155 no delay 156 no entry delay 157 nursery 158 OFF 159 o#ce 160 on 161 one 162 one hundred 163 output 164 outside 165 PANEL 166 panic 167 pantry 168 patio 169 perimeter 170 phone line 171 play 172 police 173 pool 174 pound 175 power 176 press 177 previous 178 pump 179 RADIO 180 ready 181 rear 182 relay 183 remote 184 repeat 185 rf jam 186 right 187 room 188 SAFE 189 second 190 security 191 sensor 192 sensors 193 session 194 set 195 seven 196 seventeen 197 seventy 198 shed 199 shop 200 side 201 silent 202 siren 203 six 204 sixteen 205 sixty 206 skylight 207 sliding 208 smoke 209 sounder 210 south 211 space 212 spare 213 stairs 214 star 215 status 216 stay 217 stop 218 storage 219 study 220 sump 221 supervision 222 system 223 TAMPER 224 temperature 225 ten 226 terminated 227 thermostat 228 third 229 thirteen 230 thirty 231 three 232 to 233 tool 234 transmitted 235 transmitter 236 trouble 237 turn 238 twelve 239 twenty 240 two 241 UNLOCK 242 upper 243 upstairs 244 user 245 utility 246 VALVE 247 voice 248 WALL 249 water 250 west 251 window 252 wireless 253 YARD 254 ZERO 255 zone
Docsity logo



Copyright © 2024 Ladybird Srl - Via Leonardo da Vinci 16, 10126, Torino, Italy - VAT 10816460017 - All rights reserved