Docsity
Docsity

Prepare for your exams
Prepare for your exams

Study with the several resources on Docsity


Earn points to download
Earn points to download

Earn points by helping other students or get them with a premium plan


Guidelines and tips
Guidelines and tips

Bosch solution 6000 cheat sheets, Exams of Voice

Setting up a door for access only. • Assign user to a door/s. Menu 145. • Untick “reader area control”. Menu 614. • Assign reader/keypad to a door ...

Typology: Exams

2021/2022

Uploaded on 07/05/2022

allan.dev
allan.dev 🇦🇺

4.5

(85)

1K documents

Partial preview of the text

Download Bosch solution 6000 cheat sheets and more Exams Voice in PDF only on Docsity! Bosch solution 6000 cheat sheets Adding a token to a user  Select add token and user if prompted by keypad select reader Menu 120  Select door/s that the user will have access to (if applicable) Menu 145  Select areas that the user will belong to Menu 141 Adding a keyfob  Enable the receiver - Select option 4 bosch serial receiver Menu 350  Select add keyfob and select user, then enter 9 digit code Menu 130  Select areas that the user will belong to Menu 141 Adding a Fingerprint  Select add a fingerprint Menu 180  Select door/s that the user will access to(if applicable) Menu 145  Select area's that the user will belong to Menu 141 Setting up a door for access only  Assign user to a door/s Menu 145  Untick “reader area control” Menu 614  Assign reader/keypad to a door assignment Menu 617  Set output to required function (e.g. 60 Door) Menu 411  Select event assignment (door Name) Menu 412  Select output polarity (e.g. Open one shot low = 4) Menu 413  Set time parameter for the output (e.g. 10sec) Menu 414  Set any options required for the output Menu 415 Bosch solution 6000 cheat sheets Setting up a door & User with arm, disarm & badging required  Assign user to a door/s Menu 145  Select reader & enable all on & disarming allowed. Menu 612  Select reader and enable reader badging (& egress if required) Menu 614  Select reader and enable reader area control Menu 614  Assign reader/keypad to a door assignment Menu 617  Set output to event type 60 Door Menu 411  Select event assignment (door Name) Menu 412  Select output polarity (e.g. Open one shot low = 4) Menu 413  Set time parameter for the output (e.g. 10sec) Menu 414  Set any options required for the output Menu 415 Setting up a door with D.O.T.L triggering an output  Select options for reader/keypad (e.g.; arm/disarm/part) Menu 612  If required Select reader badging & reader area control Menu 614  Assign reader/keypad to a door assignment Menu 617  Set output to required function (e.g. 60 Door) Menu 411  Select event assignment (door Name) Menu 412  Select output polarity (e.g. Open one shot low = 4) Menu 413  Set time parameter for the output (e.g. 10sec) Menu 414  Set any options required for the output Menu 415  Select a zone for D.O.T.L function in pulse count ( 13 ) Menu 313  Set D.O.T.L time frame in pulse count time Menu 314  Select the door the the D.O.T.L will work with Menu 315  Set report route in Menu 316  Set alarm condition if required for door forced Menu 423  Select output type 61 D.O.T.L alarm Menu 411  Select the door the D.O.T.L is operating on Menu 412  Set output polarity for the output. Menu 413  Set time parameter for the output Menu 414  Select output options for the output Menu 415 Bosch solution 6000 cheat sheets Communications setup Tx 1 used for the e.g. Contact ID  Select Tx 1 and set to contact id (default is C.I.D) Menu 540  Enter account number per area Menu 220  Enter base station numbers Menu 511  Test report period Menu 592  Test report route Menu 594  Open/close route Menu 222  Report route(per zone) Menu 316  Status route (system events E.g. low battery, ac fail) Menu 543  Emergency route (keypad fire, panic, medical) Menu 544 Contact ID using GSM  Select Tx 1 and set to GSM contact id (default is C.I.D) Menu 540  Enter Account number per area Menu 220  Enter base station numbers Menu 511  Test report period Menu 592  Test report route Menu 594  Open/close route Menu 222  Report route (per zone) Menu 316  Status route (system events E.g. low battery, ac fail) Menu 543  Emergency route (keypad fire, panic, medical) Menu 544 Bosch solution 6000 cheat sheets SMS  Select Tx 1 and set to sms Menu 540  Enter mobile phone numbers in Menu 511  Test report period Menu 592  Test report route Menu 594  Open/close route Menu 222  Report route (per zone) Menu 316  Status route (system events E.g. low battery, ac fail) Menu 543  Emergency route (keypad fire, panic, medical) Menu 544 SMS using GSM  Select Tx1 and set to GSM SMS (12) Menu 540  Enter mobile numbers in Menu 511  To use SMS commands to control the system enter the mobile number/s that you will be sending the command from. Menu 656  Test report period Menu 592  Test report route Menu 594  Open/close route Menu 222  Report route per zone Menu 316  Status route (system events E.g. low battery, ac fail) Menu 543  Emergency route (keypad fire, panic ,medical) Menu 544 Domestic dial  Default panel to domestic dial (only effects comms programming) Menu 703  Enter phone numbers in Menu 511 Bosch solution 6000 cheat sheets Commonly used locations  Home area Menu 613  Home area only Menu 612  Add token Menu 120  Add key fob Menu 130  Display area icons Menu 615  Enable Bosch R.F receiver (option 4) Menu 350  Turn off part arm via key fob Menu 622  Turn off audible key fob panic Menu 622  Zone array Menu 301  Operate output manually Menu 401  Output array Menu 402  Panel tamper options Menu 360  Lan scan Menu 602  E.O.L value Menu 340  Disable dialler Menu 521  Service interval Menu 292  Monitor default pin Menu 770  First to open/last to close Menu 771  Rf beep volume Menu 742  Test report time Menu 591  Test report period Menu 592  Test route Menu 594  Time/date Menu 710  Speaker beeps via key fob Menu 213  Strobe flash via key fob Menu 215  Set chime zones Menu 303  Chime mode Menu 206  Chime mode on ( Press and hold the 4 key) to toggle or use Menu 205  Zone silent alarm Menu 318  Invert zone seal Menu 318
Docsity logo



Copyright © 2024 Ladybird Srl - Via Leonardo da Vinci 16, 10126, Torino, Italy - VAT 10816460017 - All rights reserved