Download Champions School of Real Estate, 40-Hour Property & Building Inspection, Module II 2024. A and more Exams Real Estate Management in PDF only on Docsity! Champions School of Real Estate, 40- Hour Property & Building Inspection, Module II Latest 2024-2025. Questions & Correct Answers. Graded A+ _ gauge and smaller NM wire should be installed through holes in basement floor joists. - ANS#10 125amp and smaller service requires _ wire for the GEC - ANS#8awg Copper 150amp+ service requires _ wire for the GEC - ANS#6awg Copper 200amp+ service requires _ wire for the GEC - ANS#4awg Copper A cable within _ of an attic access opening is considered subject to physical damage - ANS7ft vertical, 6ft horizontal A chord and plug connected appliance should not exceed _ of a general lighting branch circuit amperage rating - ANS80% An outlet is required behind the kitchen sink if the space between it and the wall is more than 12 inches - ANSTrue An unbalanced ceiling fan is out of scope and doesn't need to be reported - ANSFalse Any point on a kitchen counter should be within _ of a receptacle - ANS2ft Any point on a wall must be within _ of a receptacle - ANS6ft Appliances that use 240v require a dedicated circuit - ANSTrue At least one GFCI protected receptacle is required in unfinished basements - ANSTrue At least one GFCI protected receptacle is required where on the exterior? - ANSThe front and back sides, as well as any porch, balcony, or deck accessible from the inside. At least one receptacle is required within _ of HVAC equipment - ANS25 ft Baffle - Water heater - ANSKeeps combustion gases in the flue longer to increase heat transfer. barometric damper - ANSA balanced air valve positioned so as to admit air to the flue or stack of a furnace in order to maintain a constant amount of draft. It is also called a draft regulator. Bathrooms don't require a dedicated circuit - ANSFalse Bend radius of cables should be - ANSFive times cable width Black NM wire might be what gauge? - ANS#8 or #6 Ceiling fans can be considered lighting fixtures - ANSFalse Convection - ANSHeat is moved by circulation of gas or liquid Countertop receptacles should be less than _ above the counter. - ANS20 inches Dip Tube - ANSroute the incoming cold water to the bottom of the heater. EGC - ANSEquipment grounding conductor Electrical equipment working area - ANS36" deep x 30" wide x 78" tall Electrolysis - ANSGalvanic reaction when dissimilar metals are ion contact in a moist environment Evaporator condensate tray may deteriorate or rust - ANSTrue Exterior receptacle must be within _ of the walking area/grade - ANS78 inches Flat NM should be stapled to framing members - ANSTrue Foyers more than 60 square ft require a receptacle on every wall that is at least 3ft wide - ANSTrue Gas Piping cannot be used as an EGC, but must be bonded to the EGC. True or False? - ANSTrue GEC - ANSGrounding electrode conductor Ground Fault - ANSWhen electricity flows through something that is not usually energized Grounding connections can be added down stream from the main panel - ANSFalse Hallways longer than _ require a receptacle - ANS10ft