Docsity
Docsity

Prepare for your exams
Prepare for your exams

Study with the several resources on Docsity


Earn points to download
Earn points to download

Earn points by helping other students or get them with a premium plan


Guidelines and tips
Guidelines and tips

Champions School of Real Estate, 40-Hour Property & Building Inspection, Module II Newest., Exams of Real Estate Management

Champions School of Real Estate, 40-Hour Property and Building Inspection, Module II Newest 2024. Questions & Correct Answers. Graded A+

Typology: Exams

2023/2024

Available from 06/12/2024

wilfred-mburu
wilfred-mburu 🇬🇧

358 documents

1 / 5

Toggle sidebar

Related documents


Partial preview of the text

Download Champions School of Real Estate, 40-Hour Property & Building Inspection, Module II Newest. and more Exams Real Estate Management in PDF only on Docsity! Champions School of Real Estate, 40- Hour Property and Building Inspection, Module II Newest 2024. Questions & Correct Answers. Graded A+ _ gauge and smaller NM wire should be installed through holes in basement floor joists. - ANS#10 125amp and smaller service requires _ wire for the GEC - ANS#8awg Copper 150amp+ service requires _ wire for the GEC - ANS#6awg Copper 200amp+ service requires _ wire for the GEC - ANS#4awg Copper A cable within _ of an attic access opening is considered subject to physical damage - ANS7ft vertical, 6ft horizontal A chord and plug connected appliance should not exceed _ of a general lighting branch circuit amperage rating - ANS80% An outlet is required behind the kitchen sink if the space between it and the wall is more than 12 inches - ANSTrue An unbalanced ceiling fan is out of scope and doesn't need to be reported - ANSFalse Any point on a kitchen counter should be within _ of a receptacle - ANS2ft Any point on a wall must be within _ of a receptacle - ANS6ft Appliances that use 240v require a dedicated circuit - ANSTrue At least one GFCI protected receptacle is required in unfinished basements - ANSTrue At least one GFCI protected receptacle is required where on the exterior? - ANSThe front and back sides, as well as any porch, balcony, or deck accessible from the inside. At least one receptacle is required within _ of HVAC equipment - ANS25 ft Baffle - Water heater - ANSKeeps combustion gases in the flue longer to increase heat transfer. barometric damper - ANSA balanced air valve positioned so as to admit air to the flue or stack of a furnace in order to maintain a constant amount of draft. It is also called a draft regulator. Bathrooms don't require a dedicated circuit - ANSFalse Bend radius of cables should be - ANSFive times cable width Black NM wire might be what gauge? - ANS#8 or #6 Ceiling fans can be considered lighting fixtures - ANSFalse Convection - ANSHeat is moved by circulation of gas or liquid Countertop receptacles should be less than _ above the counter. - ANS20 inches Dip Tube - ANSroute the incoming cold water to the bottom of the heater. EGC - ANSEquipment grounding conductor Electrical equipment working area - ANS36" deep x 30" wide x 78" tall Electrolysis - ANSGalvanic reaction when dissimilar metals are ion contact in a moist environment Evaporator condensate tray may deteriorate or rust - ANSTrue Exterior receptacle must be within _ of the walking area/grade - ANS78 inches Flat NM should be stapled to framing members - ANSTrue Foyers more than 60 square ft require a receptacle on every wall that is at least 3ft wide - ANSTrue Gas Piping cannot be used as an EGC, but must be bonded to the EGC. True or False? - ANSTrue GEC - ANSGrounding electrode conductor Ground Fault - ANSWhen electricity flows through something that is not usually energized Grounding connections can be added down stream from the main panel - ANSFalse Hallways longer than _ require a receptacle - ANS10ft
Docsity logo



Copyright © 2024 Ladybird Srl - Via Leonardo da Vinci 16, 10126, Torino, Italy - VAT 10816460017 - All rights reserved