Docsity
Docsity

Prepare for your exams
Prepare for your exams

Study with the several resources on Docsity


Earn points to download
Earn points to download

Earn points by helping other students or get them with a premium plan


Guidelines and tips
Guidelines and tips

Measuring AC Voltage Using an Oscilloscope Display - Lab 10 | PHYS 142, Lab Reports of Physics

Material Type: Lab; Class: Elementary General Physics II; Subject: Physics ; University: University of Nebraska - Lincoln; Term: Fall 2000;

Typology: Lab Reports

Pre 2010

Uploaded on 08/30/2009

koofers-user-nq0
koofers-user-nq0 🇺🇸

10 documents

1 / 10

Toggle sidebar

Related documents


Partial preview of the text

Download Measuring AC Voltage Using an Oscilloscope Display - Lab 10 | PHYS 142 and more Lab Reports Physics in PDF only on Docsity! Physics 142 - Fall 2000 11/2/00 Page 1 of 10 How Do We Sense, Think, and Move? -- Lab #10 ~ AC DC ~ Important Equipment Warnings for Today's Lesson ! • The interface should not be used to measure any voltage greater than ± 10 V. If you see that the signal from the interface is being saturated, then immediately disconnect the circuit (i.e., open the key switch). • The ammeter should not be used to measure any current greater than ± 5 A. If you see that the needle of the ammeter is pinned at maximum, then immediately disconnect the circuit (i.e., open the key switch). Task #1 - Measuring AC Voltages Using an Oscilloscope Display Oscilloscopes are one of the most common instruments used in science, medical technology, and industry and it is important that you gain experience in interpreting information from such a display. The oscilloscope has the advantage that it can collect data at a very high rate. For example, you can collect up to 250,000 samples/s when using the interface in oscilloscope mode. This makes it ideal for signals that are changing rapidly in time. Open the file Lab #10 MBL - Scope Display. You should be looking at the following display. Setting for the scale of the vertical axis (volts/division) Setting for the scale of the horizontal axis (time/division) Sampling Rate Physics 142 - Fall 2000 11/2/00 Page 2 of 10 When you monitor data, you will notice that the data constantly updates on the screen instead of scrolling off to the right. This makes it easier to analyze certain kinds of signals. Time is being displayed along the horizontal axis. You can adjust the amount of time per division with the buttons. The scale currently being used will be displayed above the buttons. Likewise, you can adjust the amount of voltage per division along the vertical direction with the pictured buttons. Keep in mind that when you change the scale on the oscilloscope display, you are only changing the way the signal is displayed, but you cannot change the actual signal with these settings. Experiment #1 – Oscilloscope display; Function generator The function generator can produce output signals of various voltages that change with time in different ways (square wave , sine wave , and triangular wave .) • Check that you have a cable with a BNC connector at one end and a double-banana plug at the other connected to the 50 Ω output. • Plug the double-banana plug into the plastic circuit block. • Set the amplitude button so that it is closer to MIN than to MAX. • Set the waveform so that the generator will produce a signal with a sine-wave shape. • Using the voltage sensor connected to Channel A of the interface, set up a circuit so that you can measure the potential difference across the double-banana plug. Be sure to note which side of the double-banana plug is ground! • Monitor the data (do not record data at this time!) when you have everything set. • You will probably need a faster sampling rate (20,000 samples/s or more!) to study the signal from the function generator. Using this circuit, discuss the answers to the following questions about the scope display with your partners. You do not need to actually write down your answers in your logbook. (a) How does the displayed signal change if you increase the V/div setting? (b) How does the displayed signal change if you decrease the V/div setting? (c) How does the displayed signal change if you increase the time/div setting? (d) How does the displayed signal change if you decrease the time/div setting? Using this circuit, discuss the answers to the following questions about the output of the function generator with your partners. You do not need to actually write down your answers in your logbook. (a) How does the signal change if you increase or decrease the setting of the frequency knob on the generator? (b) How does the signal change if you increase or decrease the value of the depressed scale button? (c) How does the signal change if you increase or decrease the setting of the amplitude knob? (Be sure to keep the amplitude less than 10 V!) Physics 142 - Fall 2000 11/2/00 Page 5 of 10 Data Collection Procedure: • Monitor the data with the Scope display. • Adjust the axes of the display so you can clearly view the behavior of the two signals. • Adjust the amplitude of VSignal so that it is about 2.0 V as displayed on the scope. This adjustment should be made using the knob on the frequency generator since you want to change the actual signal. • Slowly vary the frequency of VSignal over a large range (say 50 – 20,000 Hz). • Adjust the amplitude knob on the generator as needed to keep the amplitude of VSignal at about 2.0 V. • That is, you want the amplitude of VSignal to remain constant as you change its frequency. 2. In words, describe how the voltage across the resistor (VR) changed as you varied the frequency of VSignal. That is, describe how the frequency of VR changed (or didn't change) and describe how the amplitude of VR changed (or didn't change). If the amplitude did change, when was it largest and when was it smallest? 3. In words, describe how the rms current (Irms) passing through the circuit changed (or didn't change) as you varied the frequency of VSignal. If the current did change, when was it largest and when was it smallest? Comparison to Theory Chapter 23 of your textbook provides a theoretical discussion of the behavior of AC circuits. Based on this discussion, the authors predict the following behavior for a circuit with a resistor and an AC voltage supply. Vrms = Irms R R(f) = R Frequency (Hz) 4. Do your experimental results confirm the relation between Vrms and Irms? Explain. Hint! Pick one frequency where Irms ≠ 0 A, and measure Vrms, Irms, and R. Hint! You can measure Vrms with the digital multimeter set to AC. 5. Do your answers to questions 2-4 confirm the frequency dependence of the resistance value pictured in the graph? Explain. 6. Based on your results, sketch the rms current of this circuit as a function of frequency. Use the same frequency scale pictured in the above graph. Physics 142 - Fall 2000 11/2/00 Page 6 of 10 Experiment #3 – C Circuit; AC Signal Equipment: Signal generator, Plastic circuit block, Capacitor, Banana leads, Ammeter (AC setting), MBL voltage sensors Build the following circuit. V = Signal Generator C ≈ 0.47 µF +- A + - Com. A E B C • Hook up the Channel A MBL Voltage sensor to measure the voltage across the function generator, VEA = VSignal. • Hook up the Channel B MBL Voltage sensor to measure the voltage across the capacitor, VEB = VC. • Set the amplitude of the signal from the function generator so that it is about 2.0 V. • Set the frequency of the signal from the function generator so that it is small (~ 50 Hz). Draw a picture of the circuit in your logbook. Include the voltage sensors connected to measure VSignal and VC in your drawing. Clearly label all relevant quantities. Data Collection Procedure: • Monitor the data with the Scope display. • Slowly vary the frequency of VSignal over a large range (say 50 – 20,000 Hz). • Adjust the amplitude knob on the generator as needed to keep the amplitude of VSignal at about 2.0 V. • That is, you want the amplitude of VSignal to remain constant as you change its frequency. 7. In words, describe how the voltage across the capacitor (VC) changed as you varied the frequency of VSignal. That is, describe how the frequency of VC changed (or didn't change) and describe how the amplitude of VC changed (or didn't change). If the amplitude did change, when was it largest and when was it smallest? 8. In words, describe how the rms current (Irms) passing through the circuit changed (or didn't change) as you varied the frequency of VSignal. If the current did change, when was it largest and when was it smallest? Physics 142 - Fall 2000 11/2/00 Page 7 of 10 Comparison to Theory Based on your textbook, the authors predict the following behavior for a circuit with a capacitor and an AC voltage supply. Vrms = Irms XC XC = 1 2πfC = Capacitive Reactance Frequency (Hz) 9. Do your experimental results confirm the relation between Vrms and Irms? Explain. Hint! Pick one frequency where Irms ≠ 0 A, and measure Vrms and Irms and calculate XC. Hint! You can measure Vrms with the digital multimeter set to AC. 10. Do your answers to questions 7-9 confirm the frequency dependence of the capacitive reactance pictured in the graph? Explain. 11. Based on your results, sketch the rms current of this circuit as a function of frequency. Use the same frequency scale pictured in the above graph. Experiment #4 – L Circuit; AC Signal Equipment: Signal generator, Plastic circuit block, Inductor, Banana leads, Ammeter (AC setting), MBL voltage sensors Build the following circuit. V = Signal Generator L ≈ 25 mH A L +- A + - Com. CD • Hook up the Channel A MBL Voltage sensor to measure the voltage across the function generator, VDA = VSignal. • Hook up the Channel B MBL Voltage sensor to measure the voltage across the inductor, VDC = VL. • Set the amplitude of the signal from the function generator so that it is about 2.0 V. • Set the frequency of the signal from the function generator so that it is small (~ 50 Hz). Draw a picture of the circuit in your logbook. Include the voltage sensors connected to measure VSignal and VL in your drawing. Clearly label all relevant quantities.
Docsity logo



Copyright © 2024 Ladybird Srl - Via Leonardo da Vinci 16, 10126, Torino, Italy - VAT 10816460017 - All rights reserved