A list of maintenance and repair work orders for various building components such as drains, manholes, soakaways, masonry, brick/block repairs, concrete repairs, chimney, flashing, fascias, soffit, bargeboards, door frames, water bars, draughtproofing strips, sand and cement render, letterplates, walls, power wash, anti-graffiti paint, masonry rub down, window, gates, balustrading, staircase, gutter, pipework, bitumen paint, metalshield paint, garage door, door frame, door, window, gates, railings-ornamental, fencing, decorative stain, polyurethane lacquer, rainwater gutters, pvcu gutter, hopper, outlet, soil and vent stacks, and downpipe.

Typology: Summaries

2021/2022

Uploaded on 01/03/2024

joe-davies
joe-davies 🇬🇧

1 / 392

Toggle sidebar

Related documents


Partial preview of the text

Download Maintenance and Repair Work Orders for Various Building Components and more Summaries Mathematics in PDF only on Docsity! 240101 SCAFFOLDING:PROVIDE NE 5M HIGH NE 10M GIRTH IT Scaffolding:Provide, erect, maintain for a period not exceeding six weeks and dismantle on completion tubular steel scaffolding not exceeding 5.00m high, and not exceeding 10.00m girth, including ladders, pulley ropes, wheel fixings etc. 240103 SCAFFOLDING:PROVIDE 5M HIGH NE 20M GIRTH IT Scaffolding:Provide, erect, maintain for a period not exceeding six weeks and dismantle on completion tubular steel scaffolding not exceeding 5.00m high, over 10.00m and not exceeding 20.00m girth, including ladders, pulley ropes, wheel fixings etc. 240105 SCAFFOLDING:PROVIDE 5 TO 10M HIGH NE 5M GIRTH IT Scaffolding:Provide, erect, maintain for a period not exceeding six weeks and dismantle on completion tubular steel scaffolding over 5.00m and not exceeding 10.00m high and not exceeding 5.00m girth, including ladders, pulley ropes, wheel fixings etc. 240107 SCAFFOLDING:PROVIDE 5 TO 10M HIGH NE 10M GIRTH IT Scaffolding:Provide, erect, maintain for a period not exceeding six weeks and dismantle on completion tubular steel scaffolding over 5.00m and not exceeding 10.00m high, and over 5.00m and not exceeding 10.00m girth, including ladders, pulley ropes, wheel fixings etc. 240109 SCAFFOLDING:PROVIDE 5 TO 10M HIGH NE 20M GIRTH IT Scaffolding:Provide, erect, maintain for a period not exceeding six weeks and dismantle on completion tubular steel scaffolding over 5.00m and not exceeding 10.00m high, and over 10.00m and not exceeding 20.00m girth, including ladders, pulley ropes, wheel fixings etc. 240111 SCAFFOLDING:PROVIDE 10 TO 15M HIGH NE 5M GIRTH IT Scaffolding:Provide, erect, maintain for a period not exceeding six weeks and dismantle on completion tubular steel scaffolding over 10.00m and not exceeding 15.00m high, and not exceeding 5.00m girth, including ladders, pulley ropes, wheel fixings etc. 240113 SCAFFOLDING:PROVIDE 10 TO 15M HIGH NE 10M GIRTH IT Scaffolding:Provide, erect, maintain for a period not exceeding six weeks and dismantle on completion tubular steel scaffolding over 10.00m and not exceeding 15.00m high, and over 5.00m and not exceeding 10.00m girth, including ladders, pulley ropes, wheel fixings etc. 240115 SCAFFOLDING:PROVIDE 10 TO 15M HIGH NE 20M GIRTH IT Scaffolding:Provide, erect, maintain for a period not exceeding six weeks and dismantle on completion tubular steel scaffolding over 10.00m and not exceeding 15.00m high, and over 10.00m and not exceeding 20.00m girth, including ladders, pulley ropes, wheel fixings etc. 240117 SCAFFOLDING:PROVIDE 15 TO 20M HIGH NE 5M GIRTH IT Scaffolding:Provide, erect, maintain for a period not exceeding six weeks and dismantle on completion tubular steel scaffolding over 15.00m and not exceeding 20.00m high, and not exceeding 5.00m girth, including ladders, pulley ropes, wheel fixings etc. 240119 SCAFFOLDING:PROVIDE 15 TO 20M HIGH NE 10M GIRTH IT Scaffolding:Provide, erect, maintain for a period not exceeding six weeks and dismantle on completion tubular steel scaffolding over 15.00m and not exceeding 20.00m high, and over 5.00m and not exceeding 10.00m girth, including ladders, pulley ropes, wheel fixings etc. CR603103 GUTTER:RENEW 150MM PVCU COMPLETE LM 36.04 VE0122 FASCIA/BARGE:RENEW IN PVCU NE 300MM LM 20.12 CR438002 FASCIAS,SOFFITS ETC:PRIME PAINT TIMBER NE 300MM LM 5.28 240115 SCAFFOLD, 20WIDE X 10HIGH SM dw Balconies x5, Gutter:Renew any gutter with 150mm PVCu gutter of any profile including support brackets fixed to fascia complete with all necessary angles, outlets stop ends, including cutting, making gutters line and level and connections to existing guttering and downpipes, and remove waste and debris. Fascia/Barge:Renew fascia or bargeboard with proprietary PVCu board ne 300mm wide fixed to roof timbers with rust proofed screws,apply preservative to cut ends of any existing roof timbers, remove and refix rainwater goods and any cabling, remove existing board, adjust roof tiles and felt, renewal of any support battens and all joints, including all cutting and packing to ensure line and level and remove waste and debris. Fascias, soffits, Bargeboards and the like:Rub down, prepare for, and apply one coat primer, one undercoat, two coats of gloss paint on surfaces of facias, soffits, bargeboards and the like ne 300mm girth. £33.95 qty £2,376.50 70m £19.19 qty £1,919.00 100m £4.97 qty £347.90 70m X6 £8,001.42 £7,500.00 £20,144.82 DH0030 BATHROOM:UPGRADE TO BENCHMARK NO WC DH0031 BATHROOM:UPGRADE TO BENCHMARK WC DH0032 TOILET:UPGRADE TO BENCHMARK NO EXISTING WHB DH0033 TOILET:UPGRADE TO BENCHMARK EXISTING WHB Bathroom:Upgrade bathroom to benchmark standard disconnect and strip out existing sanitary fittings, supply and waste pipework, strip out electric wiring and light fittings, hack off wall tiling, take up and remove floor coverings, install new bath with shower/mixer taps, and basin complete, install new supply and waste pipework, complete with service valves to all appliances, install new electric wiring, switch, light and shaver fitting, low voltage transformer extract fan, make wall and ceiling finishes, supply and fix wall tiling to splashbacks and shower area, supply and lay new non-slip floor covering, redecorate, supplemental equipotential bonding and remove waste and debris. [PC Sum for supply and delivery of sanitary fittings £196.00 excluding VAT] Bathroom:Upgrade bathroom to benchmark standard disconnect and strip out existing sanitary fittings, supply soil and waste pipework, strip out electric wiring and light fittings, hack off wall tiling, take up and remove floor coverings, install new wc suite, bath with shower/mixer taps, and basin complete, install new supply, soil and waste pipework, complete with service valves to all appliances, install new electric wiring, switch, light and shaver fitting, low voltage transformer extract fan, make good wall and ceiling finishes, supply and fix wall tiling to splashbacks and shower area, supply and lay new non-slip floor covering, redecorate, supplemental equipotential bonding and remove waste and debris . [PC Sum for supply and delivery of sanitary fittings £286.00 excluding VAT] Toilet:Upgrade separate toilet to benchmark standard disconnect and strip out existing wc suite, supply and soil pipework, strip out electric wiring and light fittings, hack off any wall tiling, take up and remove floor coverings, install new wc suite, and wash hand basin complete, install new supply, soil and waste pipework, complete with service valves to all appliances, install new electric wiring, switch, light fitting, low voltage transformer extract fan, make good wall and ceiling finishes, supply and fix wall tiling to splashback, supply and lay new non-slip floor covering, redecorate, supplemental equipotential bonding and remove waste and debris. [PC Sum for supply and delivery of sanitary fittings £136.00 excluding VAT] IT 1,612.35 £1,538.18 IT 1,896.37 £1,809.14 IT 1,055.78 £1,007.21 IT 998.94 £952.99 IT 2,125.94 £2,028.15 IT 2,336.42 £2,228.94 IT 2,671.88 £2,548.97 IT 3,194.11 £3,047.18 IT 3,348.05 £3,194.04 IT 2,842.34 £2,711.59 IT 1,901.60 £1,814.13 Resp GRD041 GULLY: RENEW GRATING Resp Gully:Renew any size or type of missing or damaged gully grating Resp Resp GRD051 FENCE OR FENCE POST:EXCAVATE REMOVE AND MAKE GOOD Resp Resp Resp GRD053 TIMBER:PREPARE AND APPLY 2 COATS PRESERVATIVE Resp Resp Resp GRD055 GALLOWS GATE:RENEW Resp Resp Resp GRD057 GALLOWS GATE:EXTRA FOR GERDA H29 LOCK Resp Resp Resp Resp Resp GRD041 GULLY:RENEW GRATING Resp Gully:Renew any size or type or material of missing or damaged gully grating. Resp Resp GRD043 MANHOLE:RENEW MANHOLE COVER/FRAME Resp Resp Resp GRD045 MANHOLE:REPAIR MANHOLE COVER/FRAME Resp Resp Resp GRD047 DRAIN:CLEAR BLOCKAGE TO GULLY/DRAIN Resp Resp Resp GRD049 DRAIN:CARRY OUT CCTV SURVEY Resp Resp Resp Resp Fence Post:Excavate and remove remnants of damaged post with earth or concrete surround, fill hole with top soil, remove spoil, reinstate paving, gardens and the like. Timber:Prepare and apply two coats of brush applied preservative on existing structural or joinery timber or fencing components. Gallows Gate:Renew galvanised mild steel gallows gate ne any size including renewing posts, locks and locking mechanism fixed to brickwork or concrete, decorate, remove waste and debris. Gallows Gate; Renew or supply and fix GERDA surface mounted H29 door lock screwed, bolted or welded to gate, including making good finish to gate, provide up to 25 keys and remove waste and debris. 2.3          Drainage Manhole:Renew any type or size or weight of single seal manhole cover and frame, bed frame in mortar (1:3), remove waste and debris, reinstate level with and make good to existing finishes paving, asphalt, gardens, grounds etc as required, including providing all health and safety equipment etc. Manhole:Lift & rebed any manhole cover and frame, bed frame in mortar (1:3) incl. adjust base to ensure correct levels, clean off cover and replace incl.reset in grease, make good to existing finishes adjacent surfaces, including providing all health and safety equipment etc. Drain:Clear blockage to gully or drain including rodding as necessary, flush with clean water and removal of debris to approved tip, including providing all health and safety equipment etc and temporary fencing or barriers. Drain:Undertake CCTV survey of drain runs to identify fault or following repairs or jetting, remove and refix manhole covers and gratings, includes all hire charges supply typed report and video. 3.0          Bricklayer 3.1          Walls Resp Resp BWK001 WALL:REBOND FRACTURED BRICKWORK / BLOCKWORK Resp Resp Resp BWK002 WALL:REBOND FRACTURED BRICKWORK / BLOCKWORK HELIE Resp Resp Resp BWK003 WALL:REPOINT BRICKWORK / BLOCKWORK Resp Resp Resp BWK005 WALL:RENEW DAMAGED OR PERISHED BRICKS / BLOCKS Resp Resp Resp BWK007 WALL:REBUILD SECTION OF BOUNDARY WALL Resp Resp Resp BWK009 WALL:REPAIR OR RENEW COPING Resp Resp Resp BWK011 CILL:REPAIR QUARRY TILE OR BRICK CILL Resp Resp Resp BWK013 AIRBRICK:RENEW OR INSTALL AIRBRICK Resp Resp Resp BWK014 VENT:INSTALL PROPRIETARY VENT KIT Resp Resp Resp Resp Wall:Cut out fractured bricks or blocks as necessary to either side of fracture, stitch in new bricks or blocks to match existing, bed and point in cement mortar, make good to existing finishes both sides. Fracture up to 2 metres long. Wall:Cut out fractured bricks or blocks as necessary to either side of fracture, stitch in new bricks or blocks to match existing using Helie bars, bed and point in cement mortar, make good to existing finishes both sides. Fracture up to 2 metres long. Wall:Rake out existing joints of brickwork or blockwork, minimum 12mm deep and repoint in cement or lime mortar to match existing and remove waste and debris. Up to 2 sm. Wall:Cut out damaged/perished bricks/blocks from face of wall, clean, clear away, lay new bricks/blocks to match existing in cement mortar, bond, bed, point and remove waste and debris. Up to 10 bricks/blocks. Wall:Demolish as necessary, clean off and clear away, rebuild section of one brick boundary wall including footings in bricks to match existing, bed and point both sides in cement mortar to match existing and remove waste and debris, inclusive of temporary screens, barriers and warning notices Up to 3 sm. Wall:Repair or renew brick on edge, creasing tile or pcc copings to wall. Bed and point in cement mortar to match existing and remove waste and debris. Up to 2 metre long. Cill:Repair damaged quarry tile or brick cill. Cut out and replaced damaged tiles or bricks and lay new, bed in cement mortar to match existing and remove waste and debris. Airbrick:Renew existing or cut out for and install any type of airbrick including liner and vent, bed and point in cement mortar to match existing and remove waste and debris. Vent:Supply and install approx. 125mm diameter proprietary ventilator kit complete including core drill openings through external/internal cavity walls and install Passivent ‘Fresh99H’ humidity controlled natural vent kit and sleeving, and make good including all external and internal finishes, and remove waste and debris. 3.2          Chimneys Resp BWK015 CHIMNEY:REBUILD CHIMNEY HEAD Resp Resp Resp BWK017 CHIMNEY:REPOINT CHIMNEY Resp Resp Resp Resp Resp BWK025 FIRE:RENEW SURROUND SWEEP CHIMNEY Resp Resp Resp BWK027 FIRE:RENEW SURROUND HEARTH SWEEP CHIMNEY Resp Resp Resp BWK023 FIRE:RENEW HEARTH COMPLETE Resp Resp Resp BWK029 FIRE:REMOVE FIRE AND SEAL OPENING Resp Resp Resp Resp Resp BWK031 SURFACES:REPAIR CRACKS, CONCRETE NE 10MM Resp Resp Resp Resp Resp RFR001 RIDGE:Rebed or renew ridge, hip or valley tiles Resp Resp Resp RFR002 FLASHING:REDRESS REFIX REPAIR UBI FLEXIBLE FLASHINGS Resp Resp Chimney:Take down, rebuild chimney head, 4 courses of any size stack, clean/store bricks, rebuild, renew defective bricks, refix/renew any number of pots, liners, pcc capping, flashings, dpc, make good to existing finishes, cart away. Chimney:Rake out joints to brickwork to chimney stack, minimum 12mm, and repoint in cement mortar to match existing make good to existing finishes all works disturbed and remove waste and debris. 3.3          Fireplaces Fire:Take out fire surround and build in new tiled fireplace surround, sweep chimney, make good to existing finishes all finishings and remove waste and debris. Fire:Remove existing and renew any size tiled fireplace surround and hearth with opening size 510x575mm complete with shelf, bedded in mortar (1:1:6) make good to existing finishes, remove waste and debris. Fire:Take out tiled hearth, clear away, prepare for, supply and build in tiled hearth bedded in cement mortar, make good to existing finishes finishings, and remove waste and debris. Fire:Take out fire, surround and hearth, seal opening with brickwork or blockwork in mortar (1:1:6), cut tooth and bond to existing brickwork form opening 150x75mm for and fix plaster vent with flyscreen or closing plate for gas fire, render and set wall, including make good floor and skirting, and seal chimney cap and remove waste and debris. 3.4          Concrete Repairs Surfaces:Prepare, clean off all dust and debris, fill in or resurface cracks or spalled surfaces of concrete with epoxy mortar in general surfaces of concrete not exceeding 300mm wide, repair over 5 and ne 10mm deep, and remove waste and debris. 4.0          Roofer Ridge:Rebed or renew ridge, hip or valley tiles to match existing, bed and point with coloured cement mortar, remove waste and debris. Flashing:Redress, refix or repair flexible soaker, cover, apron or stepped flashing, clean out groove of brickwork, wedge back in lead and repoint in mastic including all necessary labours, remove waste and debris. Resp Resp Resp Resp Resp CAR007 CLADDING:REPAIR CLADDING OR BOARDING Resp Resp Resp CAR009 CLADDING:RENEW CLADDING OR BOARDING Resp Resp Resp Resp Resp CAR011 WINDOW:RENEW TIMBER DG WINDOW Resp Resp Resp CAR013 WINDOW:RENEW UPVC DG WINDOW Resp Resp Resp CAR015 WINDOW:RENEW FITTING TO TIMBER, METAL, PVC WINDOW Resp Resp Resp CAR016 WINDOW:RENEW ANY PART OF TIMBER WINDOW Resp Resp Resp Resp Resp CAR017 WINDOW:REPAIR TIMBER WINDOW OR CILL Resp Resp Resp CAR018 TIMBER:EPOXY REPAIR WINDOW OR CILL Partition:Supply and erect or renew proprietary metal stud partition comprising sole and head plate, noggins and studs fixed with nails or plugged and screwed to walls, and pack out and scribe, 12.5mm taper edged plasterboard scrim jointed and all labours to both faces. 5.3          External Cladding Cladding:Repair or minor renewal of timber or uPVC cladding or boarding including and repair or renewal of support framework and battens as required and make good to existing finishes decorations. In areas up to 5sm. Cladding:Renew timber or uPVC cladding or boarding including and repair or renewal of support framework and battens as required and make good to existing finishes decorations. In areas up to 5sm. 5.4          Window Renewals Window:Renew any timber casement window to match existing style with cill, double glazed, weatherstripping, tricke vents, ironmongery, make good to existing finishes, decorate. Window:Renew any uPVC casement window to match existing style with cill, double glazed, weatherstripping, trickle vents, ironmongery, make good to existing finishes, decorate. Window:Renew any fitting to timber, metal or uPVC window including hinges, tilt and turn mechanisms, handles, stays, locks, espagnolettes, restrictors, realign or renew sealing gaskets, renew frame sealant, renew grub screws etc, leave window in good working order. Window:Renew any timber window casement or sash to match existing renewing springs, counted weights, cords, hinges, catches, straightening sides, etc., ease and adjust openings to ensure correct operation,single glazed and decorate to match existing, leave in working order and remove waste and debris. 5.5          Window Repairs Window:Repair timber window or cill, cut out any rotten timber and splice in new sections, ensure correct operation, including renewing springs, counted weights, cords, straightening sides and re-hanging casements, hinges, etc., ease and adjust openings and leave in good working order. Resp Resp Resp CAR020 WINDOW CILL:CUT OUT AND SPLICE NEW HARDWOOD Resp Resp Resp CAR019 WINDOW:REPAIR UPVC WINDOW Resp Resp Resp CAR022 WINDOW:REPAIR UPVC WINDOW IRONMONGERY Resp Resp Resp CAR021 WINDOW:REPAIR METAL WINDOW Resp Resp Resp CAR121 WINDOW/DOOR FRAME:RAKE OUT REPOINT SEALANT Resp Resp Resp CAR123 WINDOW:RENEW WINDOW REVEALS WITH PVCU Resp Resp Resp CAR125 WINDOW: FIT CONDENSATION SILL Resp Window:Fit condensation sill to any window, drill hole and fit drain tube. Resp Resp Resp CAR023 DOOR:RENEW EXTERNAL TIMBER DOOR Resp Resp Resp CAR024 DOOR:RENEW EXTERNAL TWO ARMOUR DOOR AND FRAME Timber:Repair decayed timber window, fanlight or window cill, carefully cut away defective material, and renew sections with two part epoxy resin based filler/repair compound filling to plain surfaces and the like, any width, any depth, not exceeding 300mm long all preparatory work and making good, including renewing springs, counted weights, cords, straightening sides and re-hanging casements, hinges, etc., ease and adjust openings and leave in good working order,preparation for redecoration. Cill:Cut out and splice in new any profile 75 x 175mm treated with preservative hardwood cill to match existing frame, plugged to brickwork, and pointed with sealant, remove and refix window frame, make good plasterwork and masonry and decorate to match existing and remove waste and debris. Window:Repair uPVC window or cill, ensure correct operation, lubricate fittings, repair or renew sealing gaskets, ease and adjust openings and leave in good working order. Window:Repair uPVC window or cill, including pivot and all hinges, locks, ensure correct operation, lubricate fittings, repair or renew sealing gaskets, ease and adjust openings and leave in good working order. Window:Repair metal window including straightening frames, locks and closers, ensure correct operation, ease and adjust openings and leave in good working order. Window/Door Frame:Rake out, prepare and repoint with silicone mastic sealant complete around any door frame of any size (per face). Window:Renew window lining to cills, reveals and soffit with PVCU lining ne 350mm wide fixed with approved adhesive or other approved concealed fixing method to brickwork, make good plasterwork and decorations. 5.6          Door Renewals Door:Renew external door with any size 44mm hardwood panelled, glazed or part glazed door hang on 1.5 pair butts, fix ironmongery, weathermould, double glazed, make good to existing finishes, decorate to match existing. Resp Resp Resp CAR025 DOOR:RENEW FIRE CHECK DOOR Resp Resp Resp CAR027 DOOR:RENEW INTERNAL DOOR Resp Resp Resp CAR029 DOOR:RENEW SHED / OUTHOUSE / STORE DOOR Resp Resp Resp CAR031 DOOR:RENEW UPVC DOOR AND FRAME Resp Resp Resp Resp Resp CAR033 DOOR:REPAIR TIMBER DOOR AND / OR RENEW FITTINGS. Resp Resp Resp CAR035 DOOR:REPAIR UPVC DOOR AND / OR RENEW FITTINGS. Resp Resp Resp Resp CAR037 DOOR:REPAIR OR RENEW SLIDING DOOR MECHANISM Resp Resp Resp CAR131 DOOR:SUPPLY AND FIX WEATHERBOARD Resp Resp Resp CAR132 DOOR:CUT OPENINGS/SUPPLY AND FIX 225X150MM VENTS Door:Take out existing external door, and renew with any size ne 915 x 2130mm with multi-locking security system front entrance door and two piece armour frame fixed to existing timber frame and complete with all ironmongery, keys and key registration records, make good to existing finishes. Door:Renew fire check door to match existing style and rating, hang new door on 1.5 pairs 100mm steel hinges, fix ironmongery, intumescent strips, smoke seals, make good to existing finishes, decorate to match existing. Door:Renew internal door with any size or type to match existing, hang new door on 1 no. pair of 100mm steel butt hinges, all ironmongery, alter door blank to fit and make good door and and remake edges, make good to existing finishes and decorate. Door:Renew shed, outhouse or store door with any size softwood framed, ledged, braced door, 20mm tongued, grooved and v jointed boarding, including all ironmongery, decorate and make good to existing finishes. Door:Renew any type door and frame with any size uPVC panelled/half glazed door, double glazed uPVC frame, prehung, compl. with multipoint locking system, handles, threshold weather seals, make good to existing finishes. 5.7          Door Repairs Door:Repair any fault to timber internal or external door. Check all fittings and ironmongery and repair or renew as required, ease and adjust door and leave in good working order. Door:Repair any fault to uPVC external door. Check all fittings and ironmongery and repair or renew as required, ease and adjust door and leave in good working order. Door:Repair or renew sliding door mechanism for hanging of any internal door. Door:Supply and fix preservative treated redwood weatherboard to door, bedded and pointed in sealant, cut out base of door frame to accommodate weatherboard and decorate to match existing. [not to be claimed with any other inclusive codes] Resp Resp Resp CAR071 KITCHEN UNIT:RENEW KITCHEN WALL, FLOOR, TALL UNIT Resp Resp Resp CAR073 KITCHEN UNIT:REPAIR KITCHEN WALL, FLOOR, TALL UNIT Resp Resp Resp CAR075 KITCHEN UNIT:RENEW DRAWER PACK Resp Resp Resp CAR077 WORKTOP:RENEW KITCHEN WORKTOP Resp Resp Resp CAR079 WORKTOP:REPAIR OR REFIX KITCHEN WORKTOP Resp Resp Resp Resp CAR081 SKIRTING:REPAIR OR RENEW SKIRTING Resp Resp Resp CAR083 ARCHITRAVE:REPAIR OR RENEW ARCHITRAVE Resp Resp Resp CAR084 DADO OR PICTURE RAIL:REPAIR OR RENEW Resp Resp Resp Resp CAR085 SHELVING:RENEW AIRING CUPBOARD SHELVING Resp Resp Resp CAR087 SHELVING:REPAIR OR RENEW SHELVING Resp Kitchen Unit:Renew door or drawer front to any kitchen unit to match existing, including pair of spring loaded concealed hinges if required, fit and hang, ease and adjust. Kitchen Unit:Renew any type wall, floor or tall kitchen unit to match existing including plug scribe to walls and any necessary grounds and make good to existing finishes to all wall and ceiling finishes. Kitchen Unit:Repair, remove and later refix any type of wall, floor, tall unit, including replace panels, rehang doors, refix shelves, renew drawer runners, refix to wall and leave in good condition. Kitchen Unit:Renew any type of drawer pack to match existing, including drawer front, box and runners, leave in good working order, test. Worktop:Renew worktop to match existing incl.end/corner strips, sealant, edgings, legs, coverbeads, cut out for sink/hob, leave securely fixed to units/wall and make good to existing finishes tiled splash back. Worktop:Repair or refix any kitchen worktop including end and corner joint strips, sealant, edgings, legs, cover beads etc, make good plasterwork, tiles , grouting etc and leave in good condition. [per length of worktop] 5.14        Skirtings and Architraves Skirting:Repair or renew any type of skirting to match existing including securely fix to wall, make good to existing finishes decorations as required. Within any one room. Architrave:Repair or renew any loose or damaged architrave as required to both sides of door frame including make good to existing finishes and touch up decorations to match existing. [per door] Dado or Picture Rail:Repair or Renew any type of dado or picture rail to match existing including securely fix to wall, make good to existing finishes, decorations as required. Within any one room. 5.15        Shelving and Windowboards Shelving:Renew slatted shelving to airing cupboard complete, including slats, bearers and supports, make good to existing finishes. Shelving:Repair or renew any type of shelving or support including securely fix to brackets or wall, make good to existing finishes decorations as required. Resp Resp CAR089 WINDOWBOARDS:RENEW OR REFIX WINDOW BOARD Resp Resp Resp Resp CAR091 DUCT:RENEW OR REFIX PIPE BOXING OR DUCT Resp Resp Resp CAR092 TANK BOXING:INSTALL REPAIR REFIX OR RENEW Resp Resp Resp CAR094 BEARERS:PROVIDE NE 50 x 50MM Resp Resp Resp CAR093 BATH PANEL:REPAIR RENEW OR REFIX BATH PANEL Resp Resp Resp CAR095 CEILING HATCH:REPAIR LOFT HATCH Resp Resp Resp Resp CAR097 LETTERPLATE:RENEW LETTERPLATE TO EXTERNAL DOOR Resp Resp Resp CAR099 LOCK/LATCH:REPAIR OR RENEW LOCK OR LATCH TO DOOR Resp Resp Resp CAR120 MULTI-LOCK:REPAIR OR RENEW MULTILOCK TO DOOR Resp Resp Resp CAR101 CLOSER:REPAIR AND SERVICE DOOR CLOSER Resp Resp Resp CAR102 PADLOCK:CUT OFF AND DISPOSE Windowboard:Renew or refix any type of windowboard, plugged, screwed and pellated to brickwork, make good to existing finishes plasterwork and decorations to match existing. [Per window] 5.16        Duct Casing, Bath Panels and Ceiling Hatches Duct:Remove and refix loose or insecure pipe boxing or duct casing, including for access and including all making good and touch up to decorations. Tank Boxing:Install, repair, renew or refix tank boxing in, framing or casing of tanks, services etc, as required, securely screwed with rust proofed screws using bearers.framing not exceeding 38 x 48mm , with 15mm plywood cover including fixings, hinges and catches for access, primed and decorated to match existing. Bearers:Provide and fix timber bearers not exceeding 50 x 50 mm including plug to walls and make good and decorate to match existing. Bath Panel:Repair, renew or refix bath panel and/or framing as required, securely screwed with chromium plated dome headed screws or clipped to framing. Ceiling Hatch:Repair access hatch, framing, stops and architraves including remove and refix hatch and ironmongery as necessary and leave in working order. 5.17        Ironmongery and Draughtproofing Letterplate:Renew any type of letter plate to door, frame or wall including knocker and draught excluder if required and make good to existing finishes. Lock/Latch:Repair or renew any type of night security latch, mortice lock or mortice deadlock or mortice latch to any type of door to match existing. Leave secure and in good working order. Multilock:Repair or renew any type of multilock to any type of door to match existing. Leave secure and in good working order. Closer:Repair and service any type of door closer, perko or spring, ease, adjust and oil moving parts and leave in good working order. Resp Resp Resp CAR103 WEATHERSTRIP/DRAUGHTPROOF:RENEW OR REFIX STRIPS Resp Resp Resp Resp CAR105 OPENING:BOARD UP WITH 12MM STERLING OR PLYWOOD Resp Resp Resp CAR107 DWELLING:BOARD UP ANY TYPE COMPLETE Resp Resp Resp CAR108 DWELLING:OPEN UP COMPLETE BOARDED DWELLING Resp Resp Resp CAR109 DWELLING:GAIN ACCESS FOR EMERGENCY Resp Resp Resp CAR110 DWELLING:GAIN ACCESS FOR EVICTION Resp Resp Resp FSH040 WALL TILES:MAKE GOOD DEFECTIVE PATCH NE 0.50SM Resp Resp Resp FSH042 WALL TILES:MAKE GOOD DEFECTIVE PATCH NE 1.00SM Resp Resp Resp FSH044 WALL TILES:MAKE GOOD DEFECTIVE PATCH NE 1.50SM Padlock: Cut off existing padlock and dispose [not to be claimed with any other inclusive code] Weatherstrip/Draughtproof:Renew or refix any type of weather or draughtproof strips to door or window. 5.18        Boarding Up/Nailing Up/Re-Opening Up /Forced Entries Opening:Board up window or door with 12mm Sterling or plywood board or blockboard including cut to size, nail over window or door (NOT to frame) and leave secure (per opening). Dwelling:Board up all wdws, doors, other access to any type compl. dwelling with 12mm Sterling/plywood board/blockboard, cut to size, nail over windows, doors etc.(NOT to frames), leave secure including removing sashes and storing within dwelling. Dwelling:Remove all sterling, Sitex system, plywood or blockboard covering all window and door openings, removing all screws, nails etc, and make good all holes, splits etc and leave ready for redecoration. Dwelling:Gain access for emergency works, including force access to door, splice in new piece to frame, touch up decorations, renew lock cylinder with euro profile ‘Multilock’ cylinder to Lambeth P.I. approved pattern [large thumb- turn, removable grub screws and no hardened pins] complete with 3 no. keys and register key number and dead lock. Dwelling:Gain access for eviction with bailiff and authorised officer in attendance, including force access to door by cutting out door frame and/or cut through lock, splice in new piece to frame, touch up decorations provide new door lock and keys. Wall Tiles:Hack off glazed wall tiling in patch ne 0.50sm, renew with any size / colour tiles to match existing, bed and grout, make good to existing finishes and remove waste and debris. [not to be claimed with any other inclusive code] Wall Tiles:Hack off glazed wall tiling in patch over 0.50 and ne 1.00sm, renew with any size / colour tiles to match existing, bed and grout, make good to existing finishes and remove waste and debris. [not to be claimed with any other inclusive code] Resp Resp Resp Resp FSH023 SURFACES:REMOVE GRAFFITI Resp Resp Resp Resp Resp FSH025 WASTE CHUTE:CLEAR BLOCKAGE AT ANY POINT Resp Resp Resp Water Penetration Resp Resp FSH121 DE-HUMIDIFIER:SUPPLY TEMPORARY Resp Resp Resp FSH123 WET-VAC:SUPPLY TEMPORARY Resp Resp Resp Decoration Resp Resp FSH131 ROOM:WASH DOWN APPLY FUNGICIDAL TO SURFACES NE 6SM Resp Resp Resp FSH133 ROOM:WASH DOWN APPLY FUNGICIDAL TO SURFACES NE 12SM Resp Resp Resp FSH135 ROOM:WASH DOWN APPLY FUNGICIDAL TO SURFACES NE 18SM Resp Resp Resp FSH137 ROOM:WASH DOWN APPLY FUNGICIDAL TO SURFACES OVER 18SM 6.3          Graffiti Removal Surfaces:Clean graffiti covered surfaces with proprietary graffiti removal or stripper, apply high pressure hot water rinse to remove all traces of remover or stripper, paint, debris etc. Per wall. 6.4          Blocked Waste Chute Waste Chute:Clear blockage(s) in rubbish chute. Clean out and leave whole chute in good working order. Remove debris and clear away from site. De-humidifier:Supply, maintain and remove on completion a temporary electric de-humidifier for a period of time specified by the Client Representative, including periodic emptying. Contractor to reimburse occupier for electricity usage if dwelling tenanted. (per week). Heater:Supply, maintain and remove on completion a temporary electric wet- vac machine for a period of time specified by the Client Representative Contractor to reimburse occupier for electricity usage if dwelling tenanted. (per week). Room:Wash down, prepare, make good and apply fungicidal coating to walls and ceilings, prepare and apply two coats mould resistant glass paint to all previously painted surfaces of woodwork and metalwork, room ne 6.00 sm. Room:Wash down, prepare, make good and apply fungicidal coating to walls and ceilings, prepare and apply two coats mould resistant glass paint to all previously painted surfaces of woodwork and metalwork, room over 6.00 and ne 12.00 sm. Room:Wash down, prepare, make good and apply fungicidal coating to walls and ceilings, prepare and apply two coats mould resistant glass paint to all previously painted surfaces of woodwork and metalwork, room over 12.00 and ne 18.00sm. Resp Resp Resp FSH139 HALL:WASH DOWN APPLY FUNGICIDAL TO SURFACES NE 3SM Resp Resp Resp FSH141 HALL:WASH DOWN APPLY FUNGICIDAL TO SURFACES NE 6SM Resp Resp Resp FSH143 Resp Resp Resp FSH145 Resp Resp Resp FSH151 ROOM:REDECORATE UPTO 6SM CEILING AREA Resp Resp Resp FSH153 ROOM:REDECORATE UPTO 12SM CEILING AREA Resp Resp Resp FSH155 ROOM:REDECORATE UPTO 18SM CEILING AREA Resp Resp Resp FSH157 ROOM:REDECORATE OVER 18SM CEILING AREA Resp Resp Resp FSH159 HALLSTAIRS:REDECORATE 2 STOREY Room:Wash down, prepare, make good and apply fungicidal coating to walls and ceilings, prepare and apply two coats mould resistant glass paint to all previously painted surfaces of woodwork and metalwork, room over 18.00sm. Hall:Wash down, prepare, make good and apply fungicidal coating to walls and ceilings, prepare and apply two coats mould resistant glass paint to all previously painted surfaces of woodwork and metalwork, hall ne 3.00sm. Hall:Wash down, prepare, make good and apply fungicidal coating to walls and ceilings, prepare and apply two coats mould resistant glass paint to all previously painted surfaces of woodwork and metalwork, hall over 3.00 and ne 6.00sm. HALL/STAIRS:WASH DOWN APPLY FUNGICIDAL TO SURFACES 2 STOREY Hall/Stairs:Wash down, prepare, make good and apply fungicidal coating to walls and ceilings, prepare and apply two coats mould resistant glass paint to all previously painted surfaces of woodwork and metalwork, 2 storey. HALL/STAIRS:WASH DOWN APPLY FUNGICIDAL TO SURFACES 2 STOREY Hall/Stairs:Wash down, prepare, make good and apply fungicidal coating to walls and ceilings, prepare and apply two coats mould resistant glass paint to all previously painted surfaces of woodwork and metalwork, 3 storey. Room:Rub down, prepare for and apply two coats of emulsion to ceilings and walls, one undercoat and gloss on all painted surfaces of any room ne 6.00sm ceiling area. Room:Rub down, prepare for and apply two coats of emulsion to ceilings and walls, one undercoat and gloss on all painted surfaces of any room ne 6.00sm ceiling area. Room:Rub down, prepare for and apply two coats of emulsion to ceilings and walls, one undercoat and gloss on all painted surfaces of any room over 12.00 and ne 18.00sm ceiling area. Room:Rub down, prepare for and apply two coats of emulsion to ceilings and walls, one undercoat and gloss on all painted surfaces of any room over 18.00sm ceiling area. Resp Resp Resp FSH161 HALLSTAIRS:REDECORATE 3 STOREY Resp Resp Resp FSH163 HALL:REDECORATE COMPLETE NE 3SM CEILING AREA Resp Resp Resp FSH165 HALL:REDECORATE COMPLETE NE 6SM CEILING AREA Resp Resp Resp FSH171 ROOM:REDECORATE UPTO 6SM CEILING AREA – WALLS Resp Resp Resp FSH173 ROOM:REDECORATE UPTO 12SM CEILING AREA – WALLS Resp Resp Resp FSH175 ROOM:REDECORATE UPTO 18SM CEILING AREA – WALLS Resp Resp Resp FSH177 ROOM:REDECORATE OVER 18SM CEILING AREA – WALLS Resp Resp Resp FSH179 HALLSTAIRS:REDECORATE 2 STOREY – WALLS Resp Resp Resp FSH181 HALLSTAIRS:REDECORATE 3 STOREY – WALLS Resp Resp Resp FSH183 HALL:REDECORATE COMPLETE NE 3SM CEILING AREA – WALLS Resp Resp HallStairs:Rub down, prepare, apply two coats emulsion to ceilings, walls, one undercoat and gloss on painted surfaces of 2 storey hall, landing and staircase area (single area). HallStairs:Rub down, prepare, apply two coats emulsion to ceilings, walls, one undercoat and gloss on painted surfaces of 3 storey hall, landing and staircase area (single area). HALL:Rub down, prepare, apply two coats of emulsion to ceilings, walls, one undercoat and gloss on painted surfaces of lobby or hall ne 3.00sm ceiling area (class as single area). Hall:Rub down, prepare, apply two coats of emulsion to ceilings, walls, one undercoat and gloss on painted surfaces of corridor, lobby, hall over 3.00sm and ne 6.00sm ceiling area (single area). Room:Rub down, prepare for and apply two coats of emulsion to walls only, one undercoat and gloss on all painted surfaces of any room ne 6.00sm ceiling area. Room:Rub down, prepare for and apply two coats of emulsion to walls only, one undercoat and gloss on all painted surfaces of any room ne 6.00sm ceiling area. Room:Rub down, prepare for and apply two coats of emulsion to walls only, one undercoat and gloss on all painted surfaces of any room over 12.00 and ne 18.00sm ceiling area. Room:Rub down, prepare for and apply two coats of emulsion to d walls only, one undercoat and gloss on all painted surfaces of any room over 18.00sm ceiling area. HallStairs:Rub down, prepare, apply two coats emulsion to walls only, one undercoat and gloss on painted surfaces of 2 storey hall, landing and staircase area (single area). HallStairs:Rub down, prepare, apply two coats emulsion to walls only, one undercoat and gloss on painted surfaces of 3 storey hall, landing and staircase area (single area). HALL:Rub down, prepare, apply two coats of emulsion to walls only, one undercoat and gloss on painted surfaces of lobby or hall ne 3.00sm ceiling area (class as single area). Resp Resp Resp Resp Resp GLA005 PANE:REGLAZE SINGLE GLAZED DOOR Resp Resp Resp GLA007 PANE:REGLAZE SINGLE GLAZED WINDOW Resp Resp Resp Resp Resp GLA009 BEAD:RENEW DEFECTIVE GLAZING BEAD Resp Resp Resp GLA011 PUTTY:RENEW DEFECTIVE PUTTY TO WINDOW Resp Resp Resp Sundries Resp Resp GLA013 VENT:FIT NEW CIRCULAR TO EXISTING GLASS Resp Resp Resp Resp Resp Resp PLU001 BASIN:RENEW WHB AND/OR PEDESTAL Resp Resp Resp PLU003 BASIN:REPAIR FAULT WITH WHB AND/OR PEDESTAL Resp Resp Resp PLU005 BATH:RENEW BATH Resp Double Glazed Unit:Reglaze DGU in timber/metal/PVCu window, hermetically sealed flush edge with type/thickness of safety glass to match existing, hack out/reglaze, touch up decoration to match existing. 7.2          Single Glazing Pane:Reglaze single pane in timber/metal/PVCu door, in clear /obscure, safety glass, type/thickness to match existing, hack out/glaze with putty, sprigs, clips or beads, touch up decoration to match existing. Pane:Reglaze single pane in timber/metal/PVCu window, in clear/obscure, safety, glass, type/thickness to match existing, hack out/glaze with putty, sprigs, clips, beads, touch up decoration to match existing. 7.3          Beads and Putties Bead:Renew any type of defective glazing bead including remove existing bead, clean, prepare and supply and fit new bead to match existing, sealing with silicone sealant as necessary and decorate. [per window or door] Putty:Renew loose or defective putty, hack out old, prepare and apply new putty and touch up paintwork to match existing. [per window] Vent:Fit new 175mm plastic wind assisted circular vent with pull string to existing ne 6mm thick unwired glass of any type including carefully cut hole in glass and fit new ventilator, glass breakage is contractors risk. 8.0          Plumber 8.1          Sanitaryware Basin:Renew wash hand basin any size to match existing complete with brackets or pedestal, taps, waste, service valves, plug, chain, trap, make all connections, test, splashback, silicone sealant, crossbond. Basin:Repair any fault to wash hand basin, brackets/pedestal, leave in good working order, free flowing waste, no leaks, securely fixed, plug, chain, tile splashback, sealant all in good condition, including removing and refixing as necessary. Bath:Renew bath complete with taps, waste, plug, chain, trap service valves, bath panels, splashback, silicone sealant, make all connections, crossbond, test. Resp Resp PLU007 BATH:REPAIR FAULT WITH BATH Resp Resp Resp PLU009 BATHROOM:REPAIR OR RENEW BATHROOM FITTING Resp Resp Resp Resp Resp PLU011 TANK:RENEW STORAGE OR HEADER TANK Resp Resp Resp PLU013 CYLINDER:RENEW HOT WATER CYLINDER Resp Resp Resp Resp Resp PLU015 DOWNPIPE:RENEW DOWNPIPE N.E 2 STOREY PVCU Resp Resp Resp PLU016 DOWNPIPE:RENEW DOWNPIPE N.E 2 STOREY CAST IRON Resp Resp Resp PLU017 DOWNPIPE:RENEW DOWNPIPE EXC.2 AND N.E 4 STOREY PVCU Resp Resp Resp PLU018 DOWNPIPE:RENEW DOWNPIPE EXC.2 AND N.E 4 STOREY C.I. Resp Resp Resp PLU019 DOWNPIPE:REPAIR DOWNPIPE TO N.E 4 STOREY PVCU Resp Bath:Repair any fault with bath, leave in good working order with free flowing waste and no leaks, securely fixed, plug, chain, bath panel, framing, skirting, tile splashback, sealant all in good condition,including removing and refixing as necessary. Bathroom:Repair or renew any bathroom fitting, including hand rail, soap dish, cabinet, towel rail etc. 8.2          Tanks and Cylinders Tank:Renew any type of storage or header plastic tank, lid, jacket, ballvalve and float Byelaw 30 kit, turn water off/on, drain/refill system, adjust, connect pipework, remove old tank, test. Cylinder:Turn off/on supply, drain down/refill, renew any copper pre-insulated cylinder, remake connections, vent and test system, new immersion, remake all bonding, including disconnection, removal and refixing and reconnection of electrics. 8.3          Rainwater Goods Downpipe:Renew round or square PVCu downpipe to n.e 2 storey property complete with new brackets, branches, offset projections, hopperhead, shoe, terminal, slate, cut, make joints, make good to existing finishes. Downpipe:Renew round or square cast iron downpipe to n.e 2 storey property complete with new brackets, branches, offset projections, hopperhead, shoe, terminal, slate, cut, make joints, decorate, make good to existing finishes. Downpipe:Renew round or square PVCu downpipe to over 2 and ne 4 storey property compl. with new brackets, branches, offset projections, hopperhead, shoe, terminal, slate, cut, make joints, make good to existing finishes. Downpipe:Renew round or square cast iron downpipe to over 2 and ne 4 storey property compl. with new brackets, branches, offset projections, hopperhead, shoe, terminal, slate, cut, make joints, decorate, make good to existing finishes. Downpipe:Repair PVCU downpipe to n.e. 4 story property. Clean out/leave in good working order free flowing to drain, no leaks, securely fixed and with correct shoe or gully connection. Resp Resp PLU020 DOWNPIPE:REPAIR DOWNPIPE TO N.E 4 STOREY CAST IRON Resp Resp Resp PLU021 GUTTER:RENEW GUTTER - PER ELEVATION PVCU Resp Resp Resp PLU021 GUTTER:RENEW GUTTER - PER ELEVATION CAST IRON Resp Resp Resp PLU023 GUTTER:REPAIR GUTTER - PER ELEVATION PVCU OR CAST IRON. Resp Resp Resp Pipe Insulation Resp Resp PLU025 INSULATION:RENEW PIPE INSULATION N.E 5 LM Resp Resp Resp Overflows Resp Resp PLU027 OVERFLOW:RENEW OVERFLOW PIPEWORK Resp Resp Resp PLU029 OVERFLOW:REPAIR LEAKING OVERFLOW Resp Resp Resp Resp Resp Resp PLU101 BALLVALVE:RENEW 22MM TO 28MM DELAYED ACTION Resp Resp Resp PLU103 BALLVALVE:RENEW 35MM TO 42MM DELAYED ACTION Downpipe:Repair cast iron downpipe to n.e. 4 story property. Clean out/leave in good working order free flowing to drain, no leaks, securely fixed and with correct shoe or gully connection, touch up decorations. Gutter:Renew any PVCU gutter of any profile with support brackets, angles, outlets stop ends, cutting, making gutters line and level, connections to existing guttering and downpipes. Per elevation up to 10 metres. Gutter:Renew any cast iron gutter of any profile with support brackets, angles, outlets stop ends, cutting, making gutters line and level, connections to existing guttering and downpipes, decorate. Per elevation up to 10 metres. Gutter:Repair any gutter. Clean out and leave in good working order free flowing to outlet and no leaks to joints or stopends, line and level, securely fixed to fascia or brackets, touch up decorations if cast iron. Per elevation. Insulation:Renew or supply and fix new moulded flexible foam insulation to pipework and secure - n.e. 5 LM. Overflow:Renew overflow pipework to storage tank/header tank/cistern. Disconnect, remove existing and fit new overflow pipe, incl. fittings, clips, cut and make good to existing finishes holes/finishes as necessary. Overflow:Repair any leaking overflow to storage tank, header tank or cistern. Repair or renew ballvalve or float as required, leave in good working order with free flowing and leak free pipework. 8.4          Ballvalves Ballvalve:Turn water on and off, disconnect and remove existing ballvalve and renew with 22/28mm diameter ball valve to water cistern using delayed action flat valve as Aylesbury – K Type as manufactured by Keraflo Ltd. Resp Resp Resp PLU055 TAP:RENEW EXTERNAL TAP Resp Resp Resp PLU057 TAP:REPAIR ANY TYPE OF TAP Resp Resp Resp Appliances Resp Resp PLU059 WASHING MACHINE:PLUMB-IN APPLIANCE Resp Resp Resp PLU061 WASHING MACHINE:REPAIR FAULT TO APPLIANCE Resp Resp Resp PLU121 WASHING MACHINE:RENEW PAIR HOT AND COLD STOP TAPS Resp Resp Resp System Remedial Works Resp Resp PLU063 WATER HAMMER:CLEAR AND REMEDY AIRLOCK Resp Resp Resp PLU065 WATER SYSTEM:DRAIN DOWN DOMESTIC WATER SYSTEM Resp Resp Resp PLU067 WATER SYSTEM:RECTIFY POOR WATER PRESSURE Resp Resp Resp PLU069 WATER SYSTEM:REFILL DOMESTIC WATER SYSTEM Resp Resp Resp PLU071 WATER SYSTEM:SAFETY CHECK DOMESTIC WATER SYSTEM Tap:Renew pair of taps or mixer tap to bath, basin or sink, turn off/on water supply, disconnect, remove old, connect new taps, incl. remove/refix securely basin/sink if required, test on completion. Tap:Renew/install external 15mm brass bib tap with back plate elbow fixed to wall, hose union, loose key head, draincock, non return isolating valve, turn off/on water, extend pipework as required. Tap:Repair any type of tap. Leave in good working order incl. dismantle/renew any parts, reseating, repacking gland, resecure tap, cleaning down stem, reassemble, pack gland and test on completion. Washing Machine:Remove,s et aside and later reinstate washing machine, plumb in incl extend hot/cold pipework, fit in line stop taps/valves, make joints, test. Make connection for w.m waste in extg waste pipe incl. trap & securely fixed stand pipe. Washing Machine:Repair any fault with washing machine or dishwasher supply or waste. Leave in good working order with free flowing waste and no leaks to waste or service pipes. Washing Machine:Renew or supply and fix new pair of hot and cold in line stop taps including turn water off/on, drain/refill, fix new stop taps to existing pipework, adapt pipes, make joints, test. Water Hammer:Clear water hammer or airlock in water system, check ballvalve and taps, including turn water supply off, drain as necessary reinstate water supply. Test and provide typed report on completion. Water System:Drain down domestic water system. Turn off mains supply and drain down. Water System:Investigate and rectify poor water pressure or flow from taps. Test and provide typed report on completion. Water System:Refill hot and cold domestic water system and check incoming water supply. Resp Resp Resp PLU073 WATER SYSTEM:REPAIR LEAK TO DOMESTIC WATER SYSTEM Resp Resp Resp PLU075 MAIN:REPAIR UNDERGROUND BURST Resp Resp Resp PLU122 SUPPLY PIPE:RENEW OR REPAIR SHORT SECTION Resp Resp Resp PLU123 SUPPLY PIPE:REFIX SECTION Resp Resp Resp PLU125 SUPPLY PIPE:REMOVE SECTION Resp Resp Resp PLU127 TANK:RENEW NE 22MM BALLVALVE Resp Resp Resp PLU129 TANK:RENEW NE50MM KERAFLO FLOAT VALVE Resp Resp Resp PLU131 STOPCOCK:RENEW UP TO 22MM DIAMETER Resp Resp Resp PLU133 BALLOFIX VALVE:RENEW OR INSTALL UP TO 35MM Resp Resp Resp PLU135 SUPPLY PIPE:CAP OFF OR MINOR REPAIR Water System:Carry out safety check of complete hot and cold water plumbing and waste installation to any property and provide written report. Water System:Identify/repair leak to domestic water system. Leave in good working order incl. drain down, renew any pipework required including all bends, fittings etc. reinstate pipe lagging, clear any airlocks, test. Main:Repair copper or alkathene underground burst including turn water off/on, renew pipework, wrap pipework as necessary including all excavation backfill/cart away, reinstatement and test. Supply Pipe:Renew or install short section of pipe, any material, not exceeding 28mm diameter and not exceeding 1 metre long including all bends, connections, fittings, cutting and threading of pipes, reinstate supply, lagging and test. [not to be claimed with any other inclusive code] Supply Pipe:Refix section of supply pipe, any material, any diameter, any background complete with fittings, including refixing and renewal of any type of bracket and making good to existing. Supply Pipe:Remove section of supply pipe including fittings and brackets, not exceeding 28mm diameter, any material, not exceeding 2.00m long, including draining down and refilling. [not to be claimed with any other inclusive code] Tank:Renew 15mm or 22mm ballvalve to any tank, including draining down and refilling on completion and make good to existing. [not to be claimed with any other inclusive code] Tank:Renew 40mm or 50mm Keraflo flat valve to any tank, including draining down and refilling on completion and make good to existing. Stopcock:Renew 15mm or 22mm stopcock connected to any type of pipework including locate supply and turn water off/on, drain down/refill, adjust pipework as necessary and test, and remove waste and debris. Ballofix Valve:Renew or install any type up to 35mm Ballofix valve with and including handle connected to any type of pipework including locate supply and turn water off/on, drain down/refill, adjust pipework as necessary and test, and remove waste and debris. Resp Resp Resp Resp Resp PLU077 WC CISTERN:RENEW COMPLETE Resp Resp Resp PLU079 WC CISTERN:REPAIR CISTERN Resp Resp Resp PLU081 WC PAN:REPAIR/OVERHAUL WC PAN Resp Resp Resp PLU083 WC PAN:RENEW WC SEAT Resp WC Pan:Renew single or double flap seat and bracket to WC pan. Resp Resp PLU085 WC PAN:RENEW WC PAN COMPLETE Resp Resp Resp PLU087 WC SUITE:RENEW WC SUITE COMPLETE Resp Resp Resp Testing Resp Resp PLU141 TEST:HOT AND COLD WATER SERVICES Resp Resp Resp Sealant Joints to Sanitary Appliances and Fittings Resp Resp PLU151 SEALANT: RENEW SILICONE SEALANT Resp Resp Supply Pipe:Freeze hot or cold water pipes to isolate and carry out minor repairs, remedy leaks or cap off (low pressure) only [not to be claimed with any other inclusive code] 8.5          Water Closets WC Cistern:Renew cistern complete plugged to wall reconnect existing supply and overflow pipes, refix or flush pipework as necessary, service valve, test and make good to existing finishes all finishes. WC Cistern:Repair any fault with WC cistern. Leave in good working order with correct flushing operation, no leaks to service pipes, properly connected to WC pan and securely fixed to wall, including remove and refix if necessary. WC Pan:Repair/overhaul/unblock w.c.pan including refix seat, refix pan if loose, renew flush pipe and joint, wc cone, multikwik, remake outlet/soil pipe connections, ensure no leaking connections, test and make good to existing finishes, including remove and refix if necessary. WC Pan:Renew wc pan fixed to floor, including any plugging, renew wc cone, remake flush pipe and soil pipe joints with 'Easy-Fit' connectors, fix new plastic seat and lid to pan, make good to existing finishes, including cement and sand mounting pattress. WC Suite:Renew WC suite complete with pan and cistern, service valve, make flush, soil pipe joints with 'Easy-Fit' connectors, test all joints, plastic seat and lid, including cement and sand mounting pattress. Test:Inspect, test, locate defects in existing hort and cold water services installatiosn complete, including all tanks, cylinders, cisterns, sanitary appliances etc., provide brief typed report, including schedule of rates codes identifying repairs or defects and subsequent to their remedy, certify where necessary, the integrity of the systems [not to be claimed with any other inclusive code] Sealant: Rake out joint, clean surfaces and renew silicone rubber sealant between horizontal and vertical surfaces, to baths, basin and the like [not to be claimed for any other inclusive code] Resp Resp Resp ELE111 ROOM HEATER OR FIRE :RENEW ELECTRIC Resp Resp Resp Resp Resp ELE047 IMMERSION HEATER:RENEW IMMERSION HEATER Resp Resp Resp ELE049 IMMERSION HEATER:REPAIR IMMERSION HEATER Resp Resp Resp Resp Resp ELE051 WATER HEATER:RENEW ELECTRIC WATER HEATER Resp Resp Resp ELE053 WATER HEATER:REPAIR ELECTRIC WATER HEATER Resp Resp Resp Resp Resp ELE055 SHOWER:RENEW ELECTRIC SHOWER UNIT Resp Resp Resp ELE057 SHOWER:REPAIR ELECTRIC SHOWER UNIT Resp Resp Resp Resp Resp ELE059 LIGHT:RENEW LAMP, BULB OR TUBE TO LIGHT FITTING Resp Resp Resp ELE061 LIGHT:REPAIR OR RENEW INTERNAL LIGHT FITTING Heater:Repair any fault to electric heater or storage heater. Leave in good working order, safe, securely fixed to wall, test. Room Heater or Fire:Isolate supply, disconnect, clear away and renew room heater or fire of same output and capacity, fix to wall, make connections into spur box, reconnect electricity, tests, make good to finishings, remove debris and waste.. 9.10        Immersion Heaters Immersion Heater:Isolate/reconnect supply, drain down/refill, renew top or bottom entry immersion heater to copper cylinder, vent refix, reset thermostat, make connections, test. Immersion Heater:Repair any fault with immersion heater, thermostat, switch or flex, including isolate/reconnect supply, drain down/refill as required. Leave in good working order, test. 9.11        Water Heaters Water Heater:Isolate/reconnect supplies, drain down/refill, renew any type of instantaneous or water storage heater of same output/capacity, make good to existing finishes, test. Water Heater:Repair any fault with water heater, switch or flex, including isolate/reconnect supply, drain down/refill as required. Leave in good working order, test. 9.12        Showers Shower:Supply and install new electric shower unit, connect to water and electrical supplies including shower circuit, RCD, MCB 45A, DP switch adjust pipework fill, test, certificate, make good to existing finishes. Shower:Repair any fault with electric shower unit. Isolate/reconnect water and electric supplies, remove shower, carry out repairs. Leave in good working order, make good to existing finishes, test. 9.13        Light Fittings Light:Renew lamp, bulb or tube to any light fitting including remove and refix cover as required, test. Resp Resp Resp Resp ELE063 PROGRAMMER:RENEW OR INSTAL HEATING CONTROL TIME CLOCK Resp Resp Resp ELE065 TIME SWITCH:REPAIR OR RESET TIME SWITCH Resp Resp Resp Resp Resp ELE067 SOCKET:REPAIR OR RENEW SOCKET Resp Resp Resp ELE069 SWITCH:REPAIR OR RENEW SWITCH Resp Resp Resp ELE121 SWITCH OR OUTLET:REMOVE Resp Resp Resp Resp Resp ELE071 CIRCUIT:RENEW POWER SPUR OUTLET N.E. 10M Resp Resp Resp ELE073 CIRCUIT:RENEW TO LIGHT Resp Resp Resp ELE131 CABLE:DRAW 6MM SINGLE CABLE Resp Resp Resp ELE133 CABLE:DRAW 16MM SINGLE CABLE Resp Resp Resp Light:Isolate/reconnect supply, repair or renew any type of internal light fitting, ceiling rose, lamp holder or pendant flex. Leave in good working order, make good to existing finishes, test. 9.14        Programmers/Time Switches Programmer:Isolate/reconnect supply, renew any Economy 7 time switch clock, make all connections, test, make good to existing finishes. Time Switch:Repair or reset time switch clock or time lag switch and leave in working order. 9.15        Switches/Sockets Socket:Isolate/reconnect supply, repair or renew any type of socket outlet, box or circuit, including modifying surface trunking to suit, leave in good working order, make good to existing finishes, test. Switch:Isolate/reconnect supply, repair or renew any type of switch plate, pull switch, box or circuit, including modyifying surface trunking to suit, leave in good working order, make good to existing finishes, test. Switch or Outlet:Isolate/reconnect supply, remove any type of switch, outlet and the like including any box and associated circuit, leave rest of installation in working order, tests, make good. 9.16        Circuits Circuit:Isolate/reconnect supply, provide new 13 amp spur outlet, connect to existing ring main in mini-trunking or rigid PVC conduit ne 10m, test, certificate and make good to existing finishes. Circuit:Isolate/reconnect supply, renew one or two way lighting circuit in mini- trunking or rigid PVC conduit, switch, rose and pendant or batten holder, test, certificate and make good to existing finishes. Cable:Supply and draw 6.00mm PVC insulated single cable wire through trunking, or existing conduit to form 240/415 circuit, necessary connections, make good. Cable:Supply and draw 16.0mm PVC insulated single cable wire through trunking or existing conduit to form 240/415 circuit, make all necessary connections, make good. 9.17        Smoke Detectors Resp Resp ELE075 SMOKE DETECTOR:OVERHAUL AND SERVICE DETECTOR Resp Resp Resp ELE079 SMOKE DETECTOR:RENEW MAINS WIRED DETECTOR Resp Resp Resp Resp Resp ELE081 EXTERNAL LIGHTING:RENEW BULKHEAD FITTING Resp Resp Resp ELE083 EXTERNAL LIGHTING:REPAIR EXTERNAL LIGHTING Resp Resp Resp Resp Resp ELE085 TEST:TEST REPAIR ELECTRICS AFTER WORKS OR FLOOD Resp Resp Resp ELE087 TEST:TEST ELECTRICS AND PROVIDE REPORT Resp Resp Resp ELE141 Resp PCM PCM PCM PCM PCM PCM CR013011 STEP:REPAIR DAMAGED CONCRETE PCM PCM PCM CR013013 STEP:REFIX AND BED LOOSE STEP Smoke Detector:Overhaul and service any type of hard wired or battery operated smoke detector, vacuum through vents, test, renew battery as necessary. Smoke Detector:Renew mains operated optical or ionisation smoke detector as existing, remake connections, junction box, make good to existing finishes, test. 9.18        External Lighting External Lighting:Isolate/reconnect supply, repair any type of external light fitting switch or circuit. Leave in good working order, make good to existing finishes, test. External Lighting:Isolate/reconnect supply, renew any type of bulkhead including diffuser / cover, lamp. Leave in good working order, make good to existing finishes, test. 9.19        Testing Test:Test domestic installation complete following any repair works or flood, carry out any electric repairs required. Leave in good working order, make good to existing finishes and provide NICEIC test certificate. [not to be claimed with any other inclusive code] Test:Test domestic installation to complete, disconnect illegal wiring and components and provide report and NICEIC test certificate. [not to be claimed with any other inclusive code] 9.20        TEST: TEST ELECTRICS AND REPLACE OPEN CIRCUIT Test: Inspect, test and replace open circuit or missing London Electricity/Supply Authorities 60amp or 100amp service fuse and fuse carrier and provide report.           Planned and Cyclical Maintenance Schedule 2.0          Groundworks 2.1          Steps Step:Cut out damaged section and repair step as necessary with concrete (1:1:5:3) or cement and sand polymer enhanced cementitious mortar including formwork and trowel finish. PCM PCM PCM CR017305 FENCING:ERECT 1.8M HIGH PANEL WITH PCC POSTS PCM PCM PCM CR017314 FENCING:RENEW 0.9M HIGH PANEL PCM PCM PCM CR017310 FENCING:ERECT 1.2M HIGH PANEL WITH TIMBER POSTS PCM PCM PCM CR017312 FENCING:ERECT 1.2M HIGH PANEL WITH PCC POSTS PCM PCM Fencing - Sundry Repairs PCM PCM CR017801 FENCING:MAKE SAFE FENCING PCM PCM PCM CR017803 FENCING:RENEW TIMBER PALE AND LAG PCM PCM PCM CR017805 FENCING:REFIX TIMBER PALE AND LAG PCM PCM Fencing:Erect tanalised 1.80m high interwoven or overlap panel fencing complete consisting of interwoven or overlap fencing panels fixed with galvanised metal support brackets to and including 75x75mm fence posts, posts set in concrete, capping, 25x150mm gravel board with centre prop, allow for all necessary excavation including excavation for posts, concrete, backfill and remove waste and debris, reinstate paving and gardens as necessary (measured per metre run of fencing). Fencing:Erect tanalised 1.80m high interwoven or overlap panel fencing complete consisting of 1 interwoven or overlap fencing panels fixed with galvanised metal support brackets to and including 100x100mm pcc posts, posts set in concrete, capping 25x150mm precast concrete gravel board, allow for all necessary excavation including excavation for posts, concrete, backfill and remove waste and debris, reinstate paving and gardens as necessary (measured per metre run of fencing). Fencing:Renew any interwoven or overlap fence panel ne 1.80x0.90m fixed with galvanised metal support brackets to existing posts, remove and dismantle existing and remove waste and debris. Fencing:Erect tanalised 1.20m high interwoven or overlap panel fencing complete consisting of interwoven or overlap fencing panels fixed with galvanised metal support brackets to and including 75x75mm fence posts, posts set in concrete, capping, 25x150mm gravel board with with centre prop, allow for all necessary excavation including excavation for posts, concrete, backfill and remove waste and debris, reinstate paving and gardens as necessary (measured per metre run of fencing). Fencing:Erect tanalised 1.20m high interwoven or overlap panel fencing complete consisting of 1 interwoven or overlap fencing panels fixed with galvanised metal support brackets to and including 100x100mm pcc posts, posts set in concrete, capping 25x150mm precast concrete gravel board, allow for all necessary excavation including excavation for posts, concrete, backfill and remove waste and debris, reinstate paving and gardens as necessary (measured per metre run of fencing). Fencing:Make safe any unstable fence and or gate including but not limited to resecure and or refix fencing, brace and or reset and or refix post, rehang gate or resecure. Fencing:Renew any type of fencing pale or lag with ne 25x150mm tanalised timber including all labours, remove waste and debris. Fencing:Refix any type of fencing pale or lag including remove and refix as necessary. PCM CR017807 FENCING:FIX GALVANISED REPAIR BRACKET PCM PCM Fencing - Posts PCM CR019003 FENCE POST:REFIX LOOSE POST PCM PCM PCM CR019005 FENCE POST:RENEW TIMBER TO HARDCORE OR CONCRETE PCM PCM PCM CR019007 FENCE POST:RENEW TIMBER TO BRICKWORK PCM PCM CR019009 FENCE POST:RENEW TIMBER IN METPOST PCM PCM PCM CR019021 FENCE POST:REPAIR WITH METSPUR PCM PCM Fencing - Timber Gates PCM PCM CR021008 GATE:REPAIR AND EASE AND ADJUST TIMBER GATE PCM PCM PCM CR021012 GATE:RENEW 50X25MM STOP NE 2.0M PCM PCM CR021014 GATE:RENEW GATE AND FENCE CAPPING PCM PCM PCM CR021025 GATE:RENEW TIMBER NE 1.0SM Fencing:Supply and fix galvanised repair bracket to rail and post including all cutting and fitting to suit. Fence Post:Refix any type of loose post including reset any post set in earth or concrete without removing and refixing any post fixed to brickwork, concrete and make good. Fence Post:Renew tanalised softwood fence post set in hardcore or concrete size 100x100mm and ne 2.40m long including any struts, excavate hole, place hardcore and or concrete, backfill, remove and refix fencing, remove waste and debris, reinstate paving, gardens and the like as necessary. Fence Post:Renew tanalised softwood fence post fixed to brickwork size 100x100mm and ne 2.40m long including remove and refix fencing and or gates and drill plug and screw, remove waste and debris and make good. Fence Post:Renew 75x75mm tanalised softwood fence post ne 2.40m long with post fixed into driven or bolted Metpost including any struts, remove and refix fencing, remove waste and debris, reinstate paving, gardens and the like as necessary. Fence Post:Repair broken post with ‘Metspur’ fitting including driving spur into ground and bolting to existing post, supply all necessary struts and reinstate paths and gardens on completion, and remove waste and debris. Gate:Repair any damaged timber gate including ease and adjust, remove and rehang as necessary including adjust stop, supply and fix new timbers and scarf new sections as required and prepare for redecoration, and remove waste and debris. Gate:Renew 50x25mm tanalised softwood gate stop ne 2.00m long fixed to gate frame and redecorate to match existing, remove waste and debris. Gate:Renew any type and size of gate or fence capping with softwood tanalised capping to match and prepare for decoration. PCM PCM PCM CR021027 GATE:RENEW TIMBER NE 1.5SM PCM PCM PCM CR021029 GATE:RENEW PAIR TIMBER NE 2.5SM OVERALL PCM PCM Fencing - Metal Gates PCM CR023002 GATE:RENEW METAL NE 1.0SM PCM PCM PCM CR023004 GATE:RENEW METAL NE 2.0SM PCM PCM PCM CR023010 GATE:REPAIR AND EASE AND ADJUST METAL GATE PCM PCM Fencing - Gate Posts PCM PCM CR025002 GATE POST:RENEW TIMBER PCM PCM PCM CR025003 GATE POST:RENEW PCC Gate:Renew tanalised softwood single leaf gate ne 1.00sm overall, comprising of two 144x27mm ledges, five 144x20mm vertical boards at 175mm centres and one 144x27mm diagonal brace, including new galvanised steel strap hinges and hangers fixed to existing concrete post, new galvanised mild steel auto catch, prepare for decoration, , remove waste and debris. Gate:Renew tanalised softwood single leaf gate ne 1.50sm overall, comprising two 144x27mm ledges, five 144x20mm vertical boards at 175mm centres and one 144x27mm diagonal brace, including new galvanised steel strap hinges and hangers fixed to existing concrete post, new galvanised mild steel auto catch, prepare for decoration, , remove waste and debris. Gate:Renew tanalised softwood two leaved gate ne 2.50sm overall, each leaf comprising two 144x27mm ledges six 144x20mm vertical boards at 175mm centres and one 144x27mm diagonal brace, including new galavanised steel strap hinges and hangers fixed to existing concrete posts, new galvanised mild steel auto catch, prepare for decoration, , remove waste and debris. Gate:Renew galvanised mild steel gate ne 1.00sm, overall consisting of 25x25x3mm angle frame with corners mitred and welded and seven 10x10mm balusters with ends welded to frame, including sliding bolt, stop and one pair of hanging lugs fixed to brickwork or concrete, prepare for decoration, remove waste and debris. Gate:Renew galvanised mild steel gate ne 2.00sm overall consisting of 25x25x3mm angle frame with corners mitred and welded and seven 10x10mm balusters with ends welded to frame, including sliding bolt, stop and one pair of hanging lugs fixed to brickwork or concrete, prepare for decoration, remove waste and debris. Gate:Ease and adjust any metal gate including remove and refix and carry out any minor repairs and or adjustments as necessary, prepare for decoration. Gate Post:Renew gate post with tanalised softwood post, post size 100x125mm, set in concrete, including all excavation, concrete, backfill and remove waste and debris, reinstate paving, gardens and the like as necessary, remove and refix fencing and gates as necessary, transfer existing latch keep or gudgeon pins, prepare for decoration. PCM PCM PCM Brick/Block Repairs PCM CR101901 WALL:REPAIR FRACTURE PCM PCM PCM CR101903 WALL:REPAIR SMALL PATCH IN COMMONS PCM PCM PCM CR101905 WALL:REPAIR LARGE PATCH IN COMMONS PCM PCM PCM CR101907 WALL:REPAIR SMALL PATCH IN FACINGS PCM PCM PCM CR101909 WALL:REPAIR LARGE PATCH IN FACINGS PCM PCM Repointing PCM PCM CR102103 WALL:RAKE OUT AND REPOINT BRICKWORK PCM PCM PCM CR102105 WALL:RAKE OUT AND REPOINT JOINT OF BRICKWORK PCM PCM Cills and Thresholds PCM PCM CR103101 CILL:RENEW SINGLE QUARRY TILE PCM PCM PCM CR103105 CILL:MAKE GOOD DAMAGED CONCRETE CILL PCM PCM 5.0          Brickwork Fracture:Remove any applied finish and cut out bricks as necessary to either side of fracture, one face only, stitch in new bricks, bed and point to match existing in cement lime mortar (1:1:6), and make good any applied finishes, and remove waste and debris. (measured over mean general line of fracture). Wall:Cut out bricks from face of wall, clean and clear away, lay upto 15 No. new common bricks in cement lime mortar (1:1:6), bond, bed and point to match existing and remove waste and debris. Wall:Cut out bricks from face of wall, clean and clear away, lay over 15 No. new common bricks upto 2sm in area in cement lime mortar (1:1:6), bond, bed and point to match existing and remove waste and debris. Wall:Cut out bricks from face of wall, clean and clear away, lay upto 15 No. new facing bricks in cement lime mortar (1:1:6), bond, bed and point to match existing and remove waste and debris. Wall:Cut out bricks from face of wall, clean and clear away, lay over 15 No. new facing bricks upto 2sm in area in cement lime mortar (1:1:6), bond, bed and point to match existing and remove waste and debris. Wall:Rake out existing joints of brickwork minimum 12mm deep and repoint brickwork in mortar to match existing and remove waste and debris. Wall:Rake out existing mortar joint as necessary min 12mm and repoint in mortar to match existing in joints to cills, sides of door/window frames or concrete cladding joints etc and remove waste and debris. Cill:Renew any quarry tile to cill, bed in mortar and point to match existing including clean off and all cutting and all making good and remove waste and debris. Cill:Hack off defective area of concrete cill, clean and treat any exposed reinforcement, drill into cill and insert 6mm diameter reinforcing bars at 150mm centres, apply bonding agent and reform cill with fine concrete to match existing profiles including all necessary formwork, make good to structure and all finishes and fillets and remove waste and debris. PCM CR103109 CILL:REBED INDIVIDUAL BRICK TO CILL PCM PCM PCM CR103119 THRESHOLD:RENEW WITH PCC PCM PCM PCM CR103121 THRESHOLD:RENEW WITH INSITU CONCRETE PCM PCM Copings PCM CR103301 COPING:RENEW ISOLATED BRICK ON EDGE PCM PCM Airbricks and Vents PCM PCM CR115009 AIRBRICK:REBED LOOSE VENT PCM PCM Chimney Stacks PCM PCM CR120025 CHIMNEY:RENEW FACING BRICKS NE 6NO PCM PCM PCM CR120027 CHIMNEY:RENEW BRICKS NE 0.50SM PCM PCM PCM CR120029 CHIMNEY:RAKE OUT AND REPOINT STACK PCM PCM PCM CR120031 CHIMNEY:RENEW TWO COAT RENDER TO STACK PCM PCM PCM Flue Sundries PCM CR125010 CHIMNEY:SWEEP FLUE REGISTERED Cill:Rebed individual brick to any type of brick cill including take off, clean and rebed and point in mortar to match existing and make good to all finishes and fillets, and remove waste and debris. Threshold:Break out existing threshold and renew with precast concrete threshold size ne 80x140mm with water bar, finished fair on exposed faces and reinforced for handling as necessary and bedded and jointed in cement lime mortar (1:1:6) and remove waste and debris. Threshold:Break out existing threshold and renew with insitu concrete (1:2:4), threshold ne 80x140mm with water bar, including fix and strike formwork and finished fair on exposed faces and make good all work disturbed and remove waste and debris. Coping:Renew isolated brick in brick on edge coping including clean and prepare wall and brick and bed and point new brick in cement lime mortar (1:1:6) all to match existing and remove waste and debris. Vent:Take out loose ventilator or airbrick and rebed and point in cement lime mortar (1:1:6) to match existing. Chimney:Renew facing brick to chimney stack ne 6 No. cut out defective brick, lay new facing bricks bedded and pointed in mortar to match existing, make good all works disturbed and remove waste and debris (per brick). Chimney:Renew facing bricks in chimney stack in area ne 0.50sm, cut out defective bricks, lay new facing bricks bedded and pointed in mortar to match existing, make good all works disturbed and remove waste and debris. Chimney:Rake out joints to brickwork to chimney stack, minimum 12mm, and repoint in cement lime mortar (1:1:6) to match existing make good all works disturbed and remove waste and debris. Chimney:Renew any thickness of render to chimney, hack off, rake out, prepare and apply 18mm thick two coats cement and sand render trowelled smooth including all labours, make good all works disturbed and remove waste and debris. PCM PCM Chimney Pots, Caps, Cowls etc. PCM CR130009 CHIMNEY:REBED POT PCM PCM PCM CR130019 CHIMNEY:RENEW GALVANISED WIRE BIRDCAGE PCM PCM PCM CR130021 CHIMNEY:REMOVE AND REFIX TV AERIAL OR DISH PCM PCM Concrete Repairs PCM PCM CR146013 CONCRETE SURFACES:REPAIR CRACKS, SPALLS PCM PCM PCM CR146015 CONCRETE LINTELS:REPAIR CRACKS, SPALLS PCM PCM PCM CR146017 CONCRETE/CILLS:REPAIR CRACKS, SPALLS PCM PCM PCM CR146025 GUTTER:REPAIR FINLOCK PCM PCM PCM PCM Concrete Testing PCM PCM CR146201 CONCRETE TEST:HAMMER PCM PCM PCM CR146203 CONCRETE TEST:COVER METER SURVEY PCM PCM PCM CR146205 CONCRETE TEST:CARBONATION DEPTH TEST Chimney:Sweep flue, including protect carpets, furniture etc., and remove waste and debris, work to be undertaken by a registered chimney sweep. Chimney:Remove and refix existing pot including clean off pot and flaunching, prepare and rebed in mortar (1:3) and make good flaunching and remove waste and debris. Chimney:Renew heavy galvanised wire birdcage to any size chimney pot including removal of old cage and remove waste and debris. Chimney:Remove and refix TV Aerial or satellite dish to chimney stack including disconnection and later reconnection and testing (in conjunction with associated chimney works). Concrete Surfaces:Prepare, clean off all dust and debris, fill in or resurface cracks or spalled surfaces of concrete with epoxy mortar in general surfaces of concrete exceeding 300mm wide, repair over 5 and ne 10mm deep, and and remove waste and debris. Concrete Lintels:Prepare, clean off all dust and debris, fill in or resurface cracks or spalled surfaces of concrete with epoxy mortar in surfaces of lintels, and the like, not exceeding 300mm girth, repair over 5 and ne 10mm deep, and and remove waste and debris. Concrete/Cills:Prepare, clean off all dust and debris, fill in or resurface cracks or spalled surfaces of concrete with epoxy mortar in surfaces of lintels, and the like, not exceeding 300mm girth, repair over 10 and ne 15mm deep, and and remove waste and debris. Gutter:Repair defective joints to finlock gutter, cut out and repoint, make good, test gutter for leaks, and and remove waste and debris. Concrete Test:Hammer test all exposed surfaces of external concrete including soffits, edges and the like. Concrete Test:Cover meter survey test on all exposed surfaces of external concrete soffits. PCM PCM CR201729 VALLEY:RENEW VALLEY TILES PCM PCM PCM CR201733 VALLEY:RENEW TROUGH VALLEY TILES PCM PCM PCM Fibre Cement Slating PCM CR203101 SLATE:RENEW FIBRE CEMENT NE 5 NO PCM PCM PCM CR203107 SLATE:REFIX FIBRE CEMENT NE 5 NO PCM PCM PCM Natural Slating PCM CR203301 SLATE:RENEW NATURAL SLATE NE 5 NO PCM PCM PCM CR203307 SLATE:REFIX NATURAL SLATES OVER 5 NO PCM PCM Fibre Cement Slating – Ridge, Verge and Hip Tiles PCM PCM CR203501 RIDGE:RENEW HALF ROUND OR ROLL TOP TILE TO SLATING PCM PCM PCM CR203509 RIDGE:RENEW MONO OR DUO-PITCH TILE TO SLATING PCM PCM PCM CR203519 VERGE:RAKE OUT AND REPOINT IN MORTAR TO SLATING PCM PCM PCM Vertical Tile Hanging PCM PCM CR205001 TILE:RENEW HANGING TILE NE 10 NO Valley:Renew any type of valley tile including remove existing tile, lay new tile to bond with existing roof tiles including take up and relay adjacent tiles as necessary and remove waste and debris. Valley:Renew any type of trough valley tile including remove existing tile, lay new tile, renew any defective battens, remove and refix tiles, felt etc., to either sides of valley and remake mortar bedding and remove waste and debris. 6.2          Slate Roofing Slate:Renew fibre cement slate to roof including take out defective slate and fix new with copper nails and disc rivet including renew defective battens and felt as necessary and remove waste and debris. (in group ne 5 No). Slate:Remove and refix loose slate including fixing with new copper nails and disc rivet as necessary (in group ne 5 No.). Slate:Renew any size natural slate to roof fixed with clips or copper nails including renewing defective felt and battens as necessary and and remove waste and debris. (in group ne 5 No.). Slate:Remove and refix any size loose natural slates fixed with clips or copper nails (in group over 5 No.). Ridge:Renew half round or roll top ridge or hip tile fixed with galvanised steel clips and roofing screws with plastic washers including bedding in mastic as per manufacturers instructions and remove waste and debris. Ridge:Renew duo-pitch ridge or hip tile fixed with roofing screws with plastic washers including bedding in mastic as per manufacturers instructions and remove waste and debris. Verge:Rake out and repoint verge tiles to slate roof with coloured mortar (1:3) to match existing and remove waste and debris. 6.3          Vertical Coverings PCM PCM PCM CR205007 TILE:REFIX HANGING NE 10 NO PCM PCM PCM CR205013 TILE:RENEW FEATURE HANGING TILE PCM PCM CR205006 VERTICAL COVERING:EXTRA TO RENEW FELT AND BATTENS PCM PCM PCM CR205015 TILE:RENEW ANGLE HANGING TILE PCM PCM PCM Vertical Fibre Cement Slating PCM CR207001 SLATE:RENEW HANGING SLATE NE 5 NO PCM PCM PCM CR207007 SLATE:REFIX HANGING SLATE NE 5 NO PCM PCM PCM CR207009 SLATE:REFIX HANGING SLATE OVER 5 NO PCM PCM PCM Liquid Applied Waterproof Roof Covering PCM CR215001 ROOF:SWEEP AND APPLY WP COMPOUND PCM PCM PCM CR215003 ROOF:SEALING COMPOUND TO CRACKS PCM Roofing:Apply sealing compound to cracks to roof or leadwork. PCM PCM CR215005 ROOF:SWEEP AND APPLY BITUMEN PCM PCM PCM CR215007 ROOF:SWEEP AND APPLY STONE CHIPPINGS Tile:Renew any plain concrete or clay hanging tile (in group ne 10 No.) including remove defective tile and fix new, replace felt and battens if necessary and remove waste and debris. Tile:Remove and refix loose plain concrete or clay hanging tiles (in group ne 10 No. ). Tile:Renew patern or feature tile to tile hanging including remove tiles as necessary for access, remove defective tile and fix new and reinstate tile hanging, renew felt and battens as necessary and remove waste and debris. Vertical Covering:Extra over any renewal or refixing of roof tiles or slates for renew roofing felt and battens. Tile:Renew angle tile to tile hanging including remove tiles as necessary for access, remove defective tile and fix new and reinstate tile hanging, renew felt and battens as necessary and remove waste and debris. Slate:Renew fibre cement hanging slate including take out defective slate and fix new with copper nails, disc rivet or clips including renew defective battens and felt as necessary and remove waste and debris. (in group ne 5 No.). Slate:Remove and refix loose hanging slate including fixing with new copper nails and disc rivet or clips, renew defective felt and battens as necessary (in group ne 5 No.). Slate:Remove and refix loose hanging slates including fixing with copper nails and disc rivet or clips renew defective felt and battens as necessary (in group over 5 No.). 6.4          Remedial Works Roof:Sweep off and apply two coats of waterproofing compound and apply sand dressing between coats, and remove waste and debris. Roofing:Brush off loose chippings and clean down roof and apply three coats of bitumen compound, and remove waste and debris. PCM PCM PCM CR215009 ROOF:PREPARE AND PATCH NE 2.0SM PCM PCM CR215011 ROOF:PREPARE AND PATCH OVER 2.0SM PCM PCM PCM CR215013 GUTTER:APPLY 2 COATS WATERPROOF TO FINLOCK PCM PCM PCM Inspections PCM CR221001 CLIENT INSPECTION:PROVIDE AND ERECT LADDER PCM PCM PCM CR221003 CLIENT INSPECTION:REMOVE ALL DEBRIS ETC PCM PCM Temporary Repairs PCM PCM CR223001 ROOF:TEMPORARY REPAIR SLATE OR TILE ROOF PCM PCM PCM CR223003 ROOF:TEMPORARY REPAIR FLAT ROOF PCM PCM PCM CR223009 ROOF:TEMPORARY REPAIR CORRUGATED SHEET PCM PCM Sundry Items PCM PCM CR225001 FILLET:RENEW CEMENT MORTAR FILLET PCM PCM PCM PCM Felt Roofing – Two Layer PCM PCM CR217009 FELT:REPAIR PATCH NE 2.0SM 2L Roofing:Brush off loose chippings from roof and supply and lay limestone chippings bonded with hot bitumen compound, and remove waste and debris. Roofing:Prepare and apply two coats of approved liquid applied roof coating to roofing felt, in patches ne 2.00sm and remove waste and debris. Roofing:Prepare and apply two coats of approved liquid applied roof coating to roofing felt, in areas over 2.00sm and remove waste and debris. Gutter:Clean out gutter, rake out and apply sealant to joints and prepare and apply two coats of proprietary waterproof sealing compound to inside surfaces of Finlock gutter, and remove waste and debris. Client Inspection:Provide and erect ladder for inspection in conjunction with Client Representative to eaves level of roof to property ne 2 storey and remove on completion, and remove waste and debris. Client Inspection:Remove all debris, plant, moss etc., from roof to allow inspection for leaks and remove waste and debris. Roof:Carry out temporary repairs to any type of slate/tiled area of roof as required to ensure area is weatherproof, provide report to Client Representative. Roof:Carry out temporary repairs to any type of flat roof area as required to ensure area is weatherproof, provide report to Client Representative. Roof:Carry out temporary repairs to any type of corrugated sheet area of roof as required to ensure area is weatherproof, provide report to Client Representative. Fillet:Hack off existing and renew cement mortar fillet (1:3) and and remove suplus spoil. 6.5          Felt Roofing PCM PCM PCM CR303013 SOFFIT:RENEW IN PVCU NE 450MM PCM PCM PCM Cladding – Timber Weatherboarding – Shiplap PCM PCM CR307102 CLADDING:RENEW 19MM SHIPLAP NE 2.0SM PCM PCM PCM CR307104 CLADDING:RENEW 19MM SHIPLAP OVER 2.0SM PCM PCM PCM CR307106 CLADDING:REFIX LOOSE SHIPLAP, FEATHER EDGE OR TGV PCM PCM Cladding – Timber Weatherboarding – Feather Edge PCM PCM CR307302 CLADDING:RENEW FEATHER EDGE NE 2.0SM PCM PCM PCM CR307304 CLADDING:RENEW FEATHER EDGE OVER 2.0SM PCM PCM Cladding – Timber Weatherboarding – Softwood Tongued, Grooved and ‘V’ Jointed PCM PCM CR307502 CLADDING:RENEW T,G AND V JOINT NE 2.0SM Fascia/Barge:Renew fascia or bargeboard with proprietary PVCu board ne 300mm wide fixed to roof timbers, remove and refix rainwater goods and any cabling, remove existing board, adjust roof tiles and felt, renewal of any support battens and all joints, including all cutting and packing to ensure line and level and remove waste and debris. Soffit:Renew soffit board with PVCu board ne 450mm wide including remove existing, renew noggins as necessary and fix new board to roof timbers and refix cables and remove waste and debris. 7.2          External Cladding Cladding:Remove existing defective shiplap boarding and renew with 19mm pressure impregnated shiplap boarding in areas ne 2.00 sm including all labours, fixed to existing framework including renew defective support battens and provide any extra battens required and prepare for redecoration, and remove waste and debris. Cladding:Remove existing cladding and renew with 19mm pressure impregnated shiplap boarding in areas over 2.00 sm including all labours, fixed to existing framework including renew defective support battens and provide any extra battens required and prepare for redecoration, and remove waste and debris. Cladding:Refix loose timber shiplap, feather edge or T, G and V jointed boarding to existing framework including renewal of any support battens required and prepare for redecoration, and remove waste and debris. Cladding:Remove existing defective feather edge boarding and renew with 19mm pressure impregnated feather edge boarding in areas ne 2.00 sm including all labours, fixed to existing framework including renew defective support battens and provide any extra battens required and prepare for redecoration, and remove waste and debris. Cladding:Remove existing cladding and renew with 19mm pressure impregnated feather edge boarding to match existing in areas over 2sm including all labours, fixed to existing framework including renew defective support battens and provide any extra battens required and prepare for redecoration, and remove waste and debris. PCM PCM PCM CR307504 CLADDING:RENEW T,G AND V JOINT OVER 2.0SM PCM PCM Cladding - Plastic Profiled Sheet Cladding - Shiplap PCM PCM CR307701 CLADDING:RENEW PVC SHIPLAP NE 2.0SM PCM PCM PCM CR307703 CLADDING:RENEW PVC SHIPLAP OVER 2.0SM PCM PCM PCM CR307705 CLADDING:REFIX LOOSE PVC SHIPLAP OR TGV PCM PCM PCM Windows - Casement - Standard Softwood Double Glazed PCM PCM CR310102 WINDOW:RENEW STANDARD SOFTWOOD CASEMENT - 1 LIGHT PCM PCM PCM CR310106 WINDOW:RENEW STANDARD SOFTWOOD CASEMENT – 2 LIGHT PCM Cladding:Remove existing defective tongued, grooved and ‘V’ jointed boarding and renew with 19mm pressure impregnated tongued, grooved and ‘V’ jointed boarding in areas ne 2.00sm including all labours, fixed to existing framework, renew defective support battens and provide extra battens required and prepare for redecoration, and remove waste and debris. Cladding:Remove existing boarding and renew with 19mm tongued, grooved and V-jointed pressure impregnated softwood boarding, including all labours, in areas over 2.00sm fixed to existing framework, renew defective support battens and provide extra battens required and prepare for redecoration, and remove waste and debris. Cladding:Remove existing defective PVC shiplap cladding and renew with cellular cored PVC shiplap boarding in areas ne 2.00sm including all trims, channels and jointing, fixed to existing framework including renew defective support battens and provide any extra battens required, and remove waste and debris. Cladding:Renew cladding with cellular cored PVC shiplap boarding, in areas exc 2.00sm including all trims, channels and jointing, fixed to existing framework including renew defective support battens and provision of extra battens as necessary. Cladding:Refix loose PVC shiplap or T, G and V jointed cladding to existing framework including renewal of support battens required and all trims, channels and jointing. 7.3          Windows Window:Renew timber window with standard softwood casement window with softwood cill, including ne 1 No. opening light, factory applied base stain or primer finish, compressible weatherstripping, ironmongery including locking handles, glazing beads, windows preslotted for trickle ventilators including screens, remove existing frame and fix new in prepared opening, bed in mortar and point with sealant, double glazed, make good to all finishes, decorate to match existing internally and prepare for redecoration externally, and remove waste and debris. Window:Renew timber window with standard softwood casement window with softwood cill, including ne 2 No. opening light, factory applied base stain or primer finish, compressible weatherstripping, ironmongery including locking handles, glazing beads, windows preslotted for trickle ventilators including screens, remove existing frame and fix new in prepared opening, bed in mortar and point with sealant, double glazed, make good to all finishes, decorate to match existing internally and prepare for redecoration externally, and remove waste and debris. PCM PCM CR310110 WINDOW:RENEW STANDARD SOFTWOOD CASEMENT – 3 LIGHT PCM PCM PCM CR310114 WINDOW:RENEW STANDARD SOFTWOOD CASEMENT – 4 LIGHT PCM PCM Windows - Casement - Purpose Made Softwood Double Glazed PCM PCM CR310302 WINDOW:RENEW PURPOSE SOFTWOOD CASEMENT - 1 LIGHT PCM PCM PCM CR310306 WINDOW:RENEW PURPOSE SOFTWOOD CASEMENT - 2 LIGHT PCM PCM PCM CR310310 WINDOW:RENEW PURPOSE SOFTWOOD CASEMENT - 3 LIGHT PCM PCM PCM PCM CR310314 WINDOW:RENEW PURPOSE SOFTWOOD CASEMENT - 4 LIGHT Window:Renew timber window with standard softwood casement window with softwood cill including ne 3 No. opening light, factory applied base stain or primer finish, compressible weatherstripping, ironmongery including locking handles, glazing beads, windows preslotted for trickle ventilators including screens, remove existing frame and fix new in prepared opening, bed in mortar and point with sealant, double glazed, make good to all finishes, decorate to match existing internally and prepare for redecoration externally, and remove waste and debris. Window:Renew timber window with standard softwood casement window with softwood cill including ne 4 No. opening light, factory applied base stain or primer finish, compressible weatherstripping, ironmongery including locking handles, glazing beads, windows preslotted for trickle ventilators including screens, remove existing frame and fix new in prepared opening, bed in mortar and point with sealant, double glazed, make good to all finishes, decorate to match existing internally and prepare for redecoration externally, and remove waste and debris. Window:Renew timber window with purpose made softwood casement window with softwood cill including ne 1 No. opening light, factory applied base stain or primer finish, compressible weatherstripping, ironmongery including locking handles, glazing beads, windows preslotted for trickle ventilators including screens, remove existing frame and fix new in prepared opening, bed in mortar and point with sealant, double glazed, make good to all finishes, decorate to match existing internally and prepare for redecoration externally, and remove waste and debris. Window:Renew timber window with purpose made softwood casement window with softwood cill including ne 2 No. opening light, factory applied base stain or primer finish, compressible weatherstripping, ironmongery including locking handles, glazing beads, windows preslotted for trickle ventilators including screens, remove existing frame and fix new in prepared opening, bed in mortar and point with sealant, double glazed, make good to all finishes, decorate to match existing internally and prepare for redecoration externally, and remove waste and debris. Window:Renew timber window with purpose made softwood casement window with softwood cill including ne 3 No. opening light, factory applied base stain or primer finish, compressible weatherstripping, ironmongery including locking handles, glazing beads, windows preslotted for trickle ventilators including screens, remove existing frame and fix new in prepared opening, bed in mortar and point with sealant, double glazed, make good to all finishes, decorate to match existing internally and prepare for redecoration externally, and remove waste and debris. PCM PCM Windows - Box Sash - Purpose Made Hardwood Double Glazed PCM CR311502 WINDOW:RENEW HARDWOOD BOX SASH PCM PCM Windows - Horizontal Pivot Hung - Purpose Made Hardwood PCM PCM CR311702 WINDOW:RENEW HARDWOOD HORIZIONTAL PIVOT PCM PCM Windows - Feature – Softwood PCM PCM CR312002 WINDOW:RENEW SOFTWOOD FEATURE PCM PCM Windows - Feature - Hardwood PCM PCM PCM CR313002 WINDOW:RENEW HARDWOOD FEATURE PCM PCM Windows - Horizontal Pivot Hung - Purpose Made PVCu Window:Renew timber window with purpose made hardwood casement window with hardwood cill including ne 4 No. opening light, factory applied base stain, compressible weatherstripping, ironmongery including locking handles, glazing beads, preslotted for trickle ventilators including screens, remove existing frame and fix new in prepared opening, bed in mortar and point with sealant, double glazed, make good to all finishes, decorate to match existing internally and prepare for redecoration externally, and remove waste and debris. Window:Renew window with purpose made hardwood double hung cased box frame and sashes complete with 2 sashes, factory applied base stain, compressible weatherstripping, glazing beads, ironmongery, remove existing and fix new into prepared opening, bed in mortar, point with sealant, double glazed and make good all finishes, decorate to match existing internally and prepare for redecoration externally, and remove waste and debris. Window:Renew window with purpose made hardwood horizontal pivot hung window complete, with factory applied base stain compressible weatherstripping, glazing beads, ironmongery, fix frame to prepared opening, bed in mortar and point with sealant, double glazed, make good all finishes, decorate to match existing internally and prepare for redecoration externally, and remove waste and debris. Window:Renew timber window with standard softwood feature window ne 5.00sm overall with combination of fixed and opening lightsand panels, factory applied base stain or primer finish, compressible weatherstripping, ironmongery including locking handles, glazing beads, windows preslotted for trickle ventilators including screens, remove existing frame and fix new in prepared opening, bed in mortar and point with sealant, double glazed, decorate to match existing internally and prepare for redecoration externally, and remove waste and debris. Window:Renew timber window with standard hardwood feature window ne 5.00sm overall with combination of fixed and opening lights and panels, factory applied base stain finish, compressible weatherstripping, ironmongery including locking handles, glazing beads, windows preslotted for trickle ventilators including screens, remove existing frame and fix new in prepared opening, bed in mortar and point with sealant, double glazed, make good to all finishes, decorate to match existing internally and prepare for redecoration externally, and remove waste and debris. PCM PCM CR313501 WINDOW:RENEW WITH PVCU PIVOT PCM PCM Windows - Casement - Purpose Made PVCu PCM PCM CR313601 WINDOW:RENEW WITH PVCU CASEMENT 1 LIGHT PCM PCM PCM CR313605 WINDOW:RENEW WITH PVCU CASEMENT 2 LIGHT PCM PCM PCM CR313609 WINDOW:RENEW WITH PVCU CASEMENT 3 LIGHT PCM PCM PCM CR313613 WINDOW:RENEW WITH PVCU CASEMENT 4 LIGHT Window:Renew any type window with purpose made PVCu factory glazed horizontal pivot hung window complete with cill, double glazed internally with 20mm thick hermetically sealed units, omplete with thermal breaks, compressible weatherstripping, ironmongery including stainless steel friction hinges, espagnolette locking mechanism with locking handles, child restrictors, glazing beads, trickle ventilators including screens, remove existing and fix new to prepared opening using cleats or screw bolts, seal around externally with flexible foam strip and silicone sealant, make good all finishes internally and externally and remove waste and debris. Window:Renew any type window with purpose made PVCu factory glazed casement window with cill, double glazed internally with 20mm thick hermetically sealed units, including ne 1 No. opening light, thermal breaks, compressible weatherstripping, ironmongery including stainless steel friction hinges, espagnolette locking mechanism with locking handles, child restrictors, glazing beads, trickle ventilators including screens, remove existing and fix new to prepared opening using cleats or screw bolts, seal around externally with flexible foam strip and silicone sealant, make good all finishes internally and externally and remove waste and debris. Window:Renew any type window with purpose made PVCu factory glazed casement window with cill, double glazed internally with 20mm thick hermetically sealed units, including ne 2 No. opening light thermal breaks, compressible weatherstripping, ironmongery including stainless steel friction hinges, espagnolette locking mechanism with locking handles, child restrictors, glazing beads, trickle ventilators including screens, remove existing and fix new to prepared opening using cleats or screw bolts, seal around externally with flexible foam strip and silicone sealant, make good all finishes internally and externally and remove waste and debris. Window:Renew any type window with purpose made PVCu factory glazed casement window with cill, double glazed internally with 20mm thick hermetically sealed units, including ne 3 No. opening lights, thermal breaks, compressible weatherstripping, ironmongery including stainless steel friction hinges, espagnolette locking mechanism with locking handles, child restrictors, glazing beads, trickle ventilators including screens, remove existing and fix new to prepared opening using cleats or screw bolts, seal around externally with flexible foam strip and silicone sealant, make good all finishes internally and externally and remove waste and debris. PCM PCM Windows - Tilt and Turn - Purpose Made PVCu PCM PCM CR313701 WINDOW:RENEW WITH PVCU TILT TURN 1 LIGHT PCM PCM PCM CR313705 WINDOW:RENEW WITH PVCU TILT TURN 2 LIGHT PCM PCM PCM CR313709 WINDOW:RENEW WITH PVCU TILT TURN 3 LIGHT PCM PCM PCM CR313713 WINDOW:RENEW WITH PVCU TILT TURN 4 LIGHT Window:Renew any type window with purpose made PVCu factory glazed casement window with cill, double glazed internally with 20mm thick hermetically sealed units, including ne 4 No. opening lights, thermal breaks, compressible weatherstripping, ironmongery including stainless steel friction hinges, espagnolette locking mechanism with locking handles, child restrictors, glazing beads, trickle ventilators including screens, remove existing and fix new to prepared opening using cleats or screw bolts, seal around externally with flexible foam strip and silicone sealant, make good all finishes internally and externally and remove waste and debris. Window:Renew any type window with purpose made PVCu factory glazed tilt/turn window with cill, double glazed internally with 20mm thick hermetically sealed units, including ne 1 No. opening light, thermal breaks, compressible weatherstripping, ironmongery including stainless steel tilt and turn gear, espagnolette locking system with locking handles, glazing beads, trickle ventilators including screens, , remove existing and fix new to prepared opening using cleats or screw bolts, seal around externally with flexible foam strip and silicone sealant, make good all finishes internally and externally and remove waste and debris. Window:Renew any type window with purpose made PVCu factory glazed tilt/turn window with cill, double glazed internally with 20mm thick hermetically sealed units, including ne 2 No. opening lights, thermal breaks, compressible weatherstripping, ironmongery including stainless steel tilt and turn gear, espagnolette locking system with locking handles, glazing beads, trickle ventilators including screens, , remove existing and fix new to prepared opening using cleats or screw bolts, seal around externally with flexible foam strip and silicone sealant, make good all finishes internally and externally and remove waste and debris. Window:Renew any type window with purpose made PVCu factory glazed tilt/turn window with cill, double glazed internally with 20mm thick hermetically sealed units, including ne 3 No. opening lights, thermal breaks, compressible weatherstripping, ironmongery including stainless steel tilt and turn gear, espagnolette locking system with locking handles, glazing beads, trickle ventilators including screens, , remove existing and fix new to prepared opening using cleats or screw bolts, seal around externally with flexible foam strip and silicone sealant, make good all finishes internally and externally and remove waste and debris. PCM PCM PCM CR315036 WINDOW:RENEW GLAZING BEAD PCM PCM PCM CR315039 WINDOW:REFIX LOOSE GLAZING BEAD PCM Window:Refix loose glazing bead and bed in sealant. PCM PCM CR315042 WINDOW:RENEW CILL NOSING PCM PCM PCM CR315044 WINDOW:RENEW GLAZING BAR PCM PCM PCM CR315046 WINDOW:RENEW WEATHER MOULD PCM PCM PCM CR315048 WINDOW:REPAIR SASH RAIL OR STILE PCM PCM PCM CR315050 WINDOW:OVERHAUL TIMBER CASEMENT PCM PCM PCM CR315052 WINDOW:OVERHAUL TIMBER SASH PCM PCM Timber Window Repairs – Compounds Cill:Cut out and splice in new section over 300mm long any size or profile of preservative hardwood cill to match existing frame, plugged to brickwork, and pointed with sealant, make good plasterwork and decorate to match existing internally and prepare for redecoration externally, and remove waste and debris. Window:Renew with 14x20mm preservative treated softwood or hardwood glazing bead and prepare for redecoration, and remove waste and debris. Window:Renew front section of cill with any size or profile to match existing with screws and pellated and bed in sealant including cut out defective section and shape new to match existing, prepare for redecoration, and remove waste and debris. Window:Renew glazing bar, any size or profile to match existing, reglaze with existing glass, splice new section, remove/refix sashes as required, redecorate to match existing internally and prepare for redecoration externally (refixing of glass is Contractors risk). Window:Renew weather or parrot mould, cut out old and fix new mould, prepare for redecoration, and remove waste and debris. Window:Repair sash rail or stile any size or profile to match existing, reglaze with existing glass, splice new section, remove/refix fittings, redecorate to match existing internally and prepare for redecoration externally, (refixing of glass is Contractors risk). Window:Overhaul timber casement window, dismantle as necessary and subsequently reassemble including freeing, easing and adjusting casements to give correct operation, renew sealing gaskets, renew fixing screws, remove, refit or renew ironmongery as necessary, rake out and renew defective putty and mastic, touch up decorations internally to match existing and prepare for redecoration externally, and remove waste and debris. Window:Overhaul timber sash window, renew staff and parting beads, take out sashes and later rehang on appropriate sized new undyed plaited nylon sash cords, renew pocket pieces, wedge and cramp loose sash frames, oil pulleys, ease and adjust sashes, remove, refit or renew ironmongery, rake out and renew defective putty and mastic, touch up decorations internally to match existing and prepare for redecoration externally, and remove waste and debris. PCM CR315105 TIMBER:EPOXY REPAIR NE 10MM:OVER 300MM PCM PCM PCM CR315107 TIMBER:EPOXY REPAIRNE 10MM:NE 300MM PCM PCM PCM CR315109 TIMBER:EPOXY REPAIR NE 25MM:NE 300MM PCM PCM PCM CR315111 TIMBER:EPOXY REPAIR NE 50MM:NE 300MM PCM PCM PCM CR315113 TIMBER:EPOXY REPAIR NE 75MM:NE 300MM PCM PCM PCM CR315115 TIMBER:EPOXY REPAIR NE 25MM:NE 300MM PCM PCM PCM CR315117 TIMBER:EPOXY REPAIR NE 50MM:NE 300MM PCM Timber:Repair decayed external joinery timber, carefully cut away defective material, two part epoxy resin based filler/repair compound filling to joints, cracks, shakes, splits and the like, any width not exceeding 10mm, any depth, exceeding 300mm long all preparatory work and making good, preparation for redecoration, and remove waste and debris. Timber:Repair decayed external joinery timber, carefully cut away defective material, two part epoxy resin based filler/repair compound filling to joints, cracks, shakes, splits and the like, any width not exceeding 10mm, any depth, not exceeding 300mm long all preparatory work and making good, preparation for redecoration, and remove waste and debris. Timber:Repair decayed external joinery timber, carefully cut away defective material, two part epoxy resin based filler/repair compound filling to plain surfaces and the like, any width not exceeding 25mm, any depth, not exceeding 300mm long all preparatory work and making good, preparation for redecoration, and remove waste and debris. Timber:Repair decayed external joinery timber, carefully cut away defective material, two part epoxy resin based filler/repair compound filling to plain surfaces and the like, any width exceeding 25mm but not exceeding 50mm, any depth, not exceeding 300mm long all preparatory work and making good, preparation for redecoration, and remove waste and debris. Timber:Repair decayed external joinery timber, carefully cut away defective material, two part epoxy resin based filler/repair compound filling to plain surfaces and the like, any width exceeding 50mm but not exceeding 75mm, any depth not exceeding 300mm long all preparatory work and making good, preparation for redecoration, and remove waste and debris. Timber:Repair decayed external joinery timber, carefully cut away defective material, two part epoxy resin based filler/repair compound filling to irregular surfaces, mouldings and the like, any width not exceeding 25mm, any depth, not exceeding 300mm long all preparatory work and making good, preparation for redecoration, and remove waste and debris. Timber:Repair decayed external joinery timber, carefully cut away defective material, two part epoxy resin based filler/repair compound filling to irregular surfaces, mouldings and the like, any width exceeding 25mm but not exceeding 50mm, any depth, not exceeding 300mm long all preparatory work and making good, preparation for redecoration, and remove waste and debris. PCM PCM CR315119 TIMBER:EPOXY REPAIR NE 75MM:NE 300MM PCM PCM PCM Windows - Metal - Timber Sub-Frame PCM CR316202 WINDOW:RENEW SUB-FRAME TO METAL PCM PCM Windows - Metal - Repairs PCM CR316401 WINDOW:EASE OIL BUTTS ADJUST ANY METAL PCM PCM PCM CR316405 WINDOW:RENEW WEATHER DRAUGHT PROOFING METAL PCM PCM PCM CR316407 WINDOW:OVERHAUL METAL PCM PCM Windows - Aluminium - Repairs PCM CR317201 WINDOW:EASE OIL BUTTS ADJUST ANY ALUMINIUM PCM PCM PCM CR317205 WINDOW:OVERHAUL ALUMINIUM PCM PCM Windows PVCu - Overhaul PCM CR318301 WINDOWS/DOORS:PVCU 1 BED HOUSE CHECK CLEAN Timber:Repair decayed external joinery timber, carefully cut away defective material, two part epoxy resin based filler/repair compound filling to irregular surfaces, mouldings and the like, any width exceeding 50mm but not exceeding 75mm, any depth, not exceeding 300mm long all preparatory work and making good, preparation for redecoration, and remove waste and debris. Window:Renew timber sub-frame and cill to any steel window, including take out existing metal window and set aside, remove sub- frame, prepare for and supply and fix preservative treated softwood frame and preservative treated hardwood cill to any size or profile to match existing suit window bedded in mortar and pointed with sealant refix steel window, make good to plasterwork and cill board and redecorate to match existing internally and prepare for redecoration externally, and remove waste and debris. Window:Ease and oil butts to metal window including force open if necessary, strip paint, file and grind edges. Window:Renew proprietary weather/draught proofing to any opening light to metal window and adjust window as necessary to ensure effective operation. Window:Overhaul any type of metal window, dismantle as necessary and subsequently reassemble including freeing, easing, oiling and adjusting casements to give correct operation, including file and grind edges, renew fixing screws, remove, refit or renew ironmongery as necessary, rake out and renew defective putty and mastic, touch up decorations internally to match existing, and remove waste and debris. Window:Ease and oil butts to any type of aluminium window including renewing runners if necessary. Window:Overhaul any type of aluminium window, dismantle as necessary and subsequently reassemble including freeing, easing and adjusting casements to give correct operation, renew fixing screws, remove, refit or renew ironmongery as necessary, rake out and renew defective sealants and mastic, make good. PCM CR318103 WINDOW:RENEW SIDE HUNG PVCU SASH PCM PCM PCM CR318105 WINDOW:RENEW TRICKLE VENT TO PVCU PCM Window:Renew or repair any trickle vent to PVCu window. PCM PCM CR318107 WINDOW:RENEW HANDLE TO PVCU PCM PCM PCM CR318108 WINDOW:RENEW LOCKING HANDLE TO PVCU PCM PCM PCM CR318109 WINDOW:RENEW HINGE TO PVCU PCM PCM PCM CR318111 WINDOW:RENEW ESPAGNOLETTE LOCK TO PVCU PCM PCM PCM CR318113 WINDOW:RENEW SEALING GASKET TO PVCU PCM PCM PCM CR318115 WINDOW:CHECK LUBRICATE FITTINGS TO PVCU PCM PCM PCM CR318117 WINDOW:EASE AND ADJUST PVCU SASH PCM Window:Ease and adjust PVCu sash including realign as necessary. PCM PCM CR318119 WINDOW:OVERHAUL TILT TURN MECHANISM TO PVCU PCM PCM PCM CR318121 WINDOW:RENEW TILT TURN MECHANISM TO PVCU PCM PCM PCM CR318123 WINDOW:CHILD RESTRICTOR TO PVCU PCM PCM CR318125 WINDOW:OVERHAUL PVCU Window:Renew any size and type of sidehung sash to PVCu window including double glazing and all ironmongery and make good. Window:Renew any defective or broken handle to PVCu window including remove existing, check, lubricate operating mechanism, renew handle to match existing and test. Window:Renew any defective or broken locking handle to PVCu window including remove existing, check, lubricate operating mechanism, renew handle to match existing and test. Window:Renew any defective or broken hinge to PVCu window including remove existing and renew hinge to match existing, and remove waste and debris. Window:Renew any defective or broken espagnolette locking mechanism to PVCu window including remove existing and renew to match existing and and test. Window:Renew sealing gasket to any opening light of PVCu window (per opening light). Window:Check operation of all fittings and operating mechanisms to PVCu window complete including lubricate and adjust as necessary. Window:Check operation of tilt and turn mechanism to PVCu window including overhaul, lubricate and adjust as necessary. Window:Renew any tilt and turn mechanism complete to PVCu window of any size to match existing, including remove existing, test and leave in proper working order. Window:Renew or supply and fix new adjustable child proof restrictor/catch to any type of PVCu window including removing existing fitting. PCM PCM Windows and Door Frames – Silicone Pointing PCM CR318201 DOOR FRAME:RAKE OUT AND REPOINT SEALANT PCM PCM PCM CR318203 WINDOW FRAME:RAKE OUT AND REPOINT PCM PCM PCM Windows - Roof PCM CR319001 ROOF WINDOW:RENEW NE 0.78X0.98M PCM PCM PCM CR319003 ROOF WINDOW:RENEW NE 1.14X1.18MM PCM PCM PCM CR319005 ROOF WINDOW:RENEW NE 1.34X1.40MM PCM PCM Windows - Roof - Repairs PCM CR319101 ROOF WINDOW:REDRESS FLASHINGS PCM PCM PCM CR319103 ROOF WINDOW:OVERHAUL OPENING GEAR PCM Roof Window:Overhaul opening gear to any type of roof window. PCM PCM CR319105 ROOF WINDOW:RENEW CONTROL CORDS PCM Roof Window:Renew operating control cords to any roof window. PCM External Doors PCM Doors - External Panelled or Glazed - Hardwood - Standard PCM CR321106 DOOR:RENEW HW PANELLED OR GLAZED BACK DOOR Window:Overhaul any type of pvcu window, dismantle as necessary and subsequently reassemble including freeing, easing and adjusting casements to give correct operation, renew fixing screws, remove, refit or renew ironmongery as necessary, check, lubricate operating mechanism, renew gaskets, make good and test. Door Frame:Rake out, prepare and repoint with silicone mastic sealant complete around any door frame of any size. (per face). Window Frame:Rake out, prepare and repoint with silicone mastic sealant complete around any window frame (per face). Roof Window:Renew roof window complete size ne 0.78 x 0.98m with Velux aluminium clad externally roof window with factory fitted clear float double glazed sealed unit, all upstands, flashings and dressing of flashings, fixing to timber with screws and make good all finishings internally and roof coverings externally, and remove waste and debris. Roof Window:Renew roof window complete size ne 1.14 x 1.18mm with Velux aluminium clad externally roof window with factory fitted clear float double glazed sealed unit, all upstands, flashings and dressing of flashings, fixing to timber with screws and make good all finishings internally and roof coverings externally, and remove waste and debris. Roof Window:Renew roof window complete size ne 1340 x 1400mm with Velux aluminium clad externally roof window with factory fitted clear float double glazed sealed unit, all upstands, flashings and dressing of flashings, fixing to timber with screws and make good all finishings internally and roof coverings externally, and remove waste and debris. Roof Window:Redress roof flashings around roof window and reseal to prevent water penetration. PCM PCM PCM CR321108 DOOR:RENEW HW PANELLED OR GLAZED FRONT DOOR PCM PCM Doors – External Panelled or Glazed - Hardwood - Purpose Made PCM PCM CR321306 DOOR:RENEW PM HW PANELLED OR GLAZED BACK DOOR PCM PCM PCM CR321308 DOOR:RENEW PM HW PANELLED OR GLAZED FRONT DOOR PCM PCM Doors - External Panelled or Glazed - Softwood - Standard PCM CR321506 DOOR:RENEW SW PANELLED OR GLAZED BACK DOOR PCM PCM PCM CR321508 DOOR:RENEW SW PANELLED OR GLAZED FRONT DOOR Door:Renew back door with any size 44mm hardwood panelled, glazed or part glazed door prepared for glazing, hang on 1.5 pair butts, fix new mortice lock, furniture, keep, pair of bolts, hardwood weathermould, adjust stops and ease rebates, cut out and make good to frame to suit new position of hinges, weathermould and lock, rebate door bottom as necessary and fit new water bar if required, double glazed and decorate to match existing internally and prepare for redecoration externally, and remove waste and debris. Door:Renew front door with any size 44mm hardwood panelled, glazed or part glazed door prepared for glazing, hang on 1.5 pair butts, fix new mortice lock, furniture, keep, pair of bolts, cylinder latch and pull, security restraint device, letter plate including cutting mortice in door to suit, numerals, hardwood weathermould, adjust stops, ease rebates, cut out and make good to frame to suit new position of butts, weathermould, lock and latch, rebate door bottom as necessary and fit new waterbar if required, double glazed and decorate to match existing internally and prepare for redecoration externally, and remove waste and debris. Door:Renew back door with any size 44mm hardwood panelled, glazed or part glazed purpose made door prepared for glazing, hang on 1.5 pair butts, fix new mortice lock, furniture, keep, pair of bolts, hardwood weathermould, adjust stops and ease rebates, cut out and make good to frame to suit new position of hinges, weathermould and rebate door bottom as necessary and fit new water bar if required, double glazed and decorate to match existing internally and prepare for redecoration externally, and remove waste and debris. Door:Renew front door with any size 44mm hardwood panelled, glazed or part glazed purpose made door prepared for glazing, hang on 1.5 pair butts, fix new mortice lock, furniture, keep, pair of bolts, cylinder latch and pull, security restraint device, letter plate including cutting mortice in door to suit, numerals, hardwood weathermould, adjust stops, ease rebates, cut out and make good to frame to suit new position of butts, weathermould, lock and latch, rebate door bottom as necessary and fit new waterbar if required, double glazed and decorate to match existing internally and prepare for redecoration externally, and remove waste and debris. Door:Renew back door with any size 44mm softwood panelled, glazed or part glazed door prepared for glazing, hang on 1.5 pair butts, fix new mortice lock, furniture, keep, pair of bolts, softwood weathermould, adjust stops and ease rebates, cut out and make good to frame to suit new position of hinges, weathermould and lock, rebate door bottom as necessary and fit new water bar if required, double glazed and decorate to match existing internally and prepare for redecoration externally, and remove waste and debris. PCM PCM PCM CR323505 DOOR:RENEW PVCU PANEL GLAZED DOOR PCM PCM PCM CR323507 DOOR:RENEW PVCU 2 PANEL DOOR PCM PCM PCM CR323509 DOOR:RENEW PVCU TILT AND TURN FRENCH DOOR PCM PCM PCM Doors - External - High Performance PVCu Residential Type PCM CR323601 DOOR:HIGH PERFORMANCE PVCU BACK DOOR PCM PCM PCM CR323603 DOOR:HIGH PERFORMANCE PVCU FRONT DOOR PCM Door:Renew any type door and frame with any size PVCu two panel/half glazed door, double glazed internally with 20mm thick, hermetically sealed unit, PVCu frame, prehung, complete with multipoint locking system, handles, threshold and integral weather seals, remove existing and fix new to prepared opening using cleats or screw bolts, seal around externally with flexible foam strip and silicone sealant, make good all finishes internally and externally, and remove waste and debris. Door:Renew any door with any size PVCu panelled/half glazed door, double glazed internally with 20mm thick hermetically sealed unit hanging to existing PVCu frame on new hinges, complete with multipoint locking system, handles, threshold and integral weather seals, remove existing door and clear away, make good all finishes internally and externally, and remove waste and debris. Door:Renew any door with any size PVCu two panel/half glazed door, double glazed internally with 20mm thick hermetically sealed unit hanging to existing PVCu frame on new hinges, complete with multipoint locking system, handles, threshold and integral weather seals, remove existing door and clear away, make good all finishes internally and externally, and remove waste and debris. DOOR:Renew any type door and frame with pair of any size ne 5.00sm PVCu french tilt/turn door, double glazed internally 20mm thick, hermetically sealed unit, PVCu frame, prehung, complete with multipoint locking system, handles, threshold and integral weather seals, remove existing and fix new to prepared opening using cleats or screw bolts, seal around externally with flexible foam strip and silicone sealant, make good all finishes internally and externally, and remove waste and debris. Door:Renew back door with any size panelled, glazed or partially glazed or similar proprietary high performance PVCu door, prefinished and preglazed, hang on 1.5 pair butts, fix new mortice lock, door furniture, keeps, pair of bolts, proprietary weathermould, adjust stops and ease rebates, cut out and make good to frame to suit new position of hinges, weathermould and lock, rebate door bottom as necessary and fit new water bar if required, and remove waste and debris. Door:Renew front door with any size panelled, glazed or partially glazed or similar proprietary high performance PVCu door, prefinished and preglazed, hang on 1.5 pair butts, fix new mortice lock, door furniture, keeps, pair of bolts, cylinder nightlatch and pull, security restraint device, proprietary letter plate including cutting mortice in door to suit, numerals, proprietary weathermould, adjust stops and ease rebates, cut out and make good to frame to suit new position of butts, weathermould, lock and lock, rebate door bottom as necessary and fit new waterbar if required, and remove waste and debris. PCM Doors - External - Repairs - Timber PCM CR324102 DOOR:EASE AND ADJUST INCLUDING REMOVE PCM PCM PCM CR324107 DOOR:REFIX LOOSE GLAZING BEADS PCM PCM PCM CR324110 DOOR:RENEW PLYWOOD PANEL PCM PCM PCM ER324112 DOOR:PATCH OR REPAIR DOOR STILE PCM PCM PCM CR324114 DOOR:RENEW SOFTWOOD DOOR STILE PCM PCM CR324116 DOOR:SUPPLY AND FIX WEATHERBOARD PCM PCM CR324117 DOOR:PROVIDE HARDWOOD RAIN DEFLECTOR PCM PCM PCM CR324120 DOOR:RENEW HARDWOOD GLAZING BEADS PCM PCM PCM CR324122 DOOR:RENEW HARDWOOD DOOR STILE PCM PCM Door:Ease and adjust door, hung on upto 1.5 pairs of butt hinges, including remove and rehang door and make good to butt recesses to frame and prepare for redecoration, and remove waste and debris. Door:Refix loose glazing beads including bedding and sealing with sealant. (per door). Door:Renew 9mm external quality plywood panel size 610x610mm to door, including remove weather- seal, refix or renew beads, renew weatherseal and decorate to match existing internally and prepare for redecoration externally, and remove waste and debris. Door:Patch, repair hanging or closing stile of softwood door including cut out and splice in new timber upto 600mm long, and decorate to match existing internally and prepare for redecoration externally, and remove waste and debris. Door:Renew closing stile to softwood door, remove glass or plywood panels and beads and set aside, take down door and remove hinges, remove iron- mongery and set aside, cut out defective stile to top, middle and bottom rails, refix glass or plywood panels and beads, refix ironmongery, ease and adjust door, and decorate to match existing internally and prepare for redecoration externally, and remove waste and debris. Door:Supply and fix preservative treated redwood weatherboard to door, bedded and pointed in sealant, cut out base of door frame to accomodate weatherboard and prepare for redecoration, and remove waste and debris. Door:Supply and fix 50mm x 19mm hardwood bevelled rain deflector with neoprene or rubber flexible pad at bottom, bedded in sealant and screwed to face of door. Door:Renew with preservative treated hardwood rebated splayed and twice rounded glazing beads of any size and of any profile including mitres and ends, bedding and pointing with sealant and prepare for redecoration, and remove waste and debris. Door:Renew closing stile to hardwood door, remove glass or plywood panels and beads and set aside, take down door and remove hinges, remove iron- mongery and set aside, cut out defective stile to top, middle and bottom rails, refix glass or plywood panels and beads, refix ironmongery, ease and adjust door, and prepare for redecoration, and remove waste and debris. PCM CR324123 DOOR:OVERHAUL EXTERNAL COMPLETE PCM PCM PCM CR324125 DOOR:OVERHAUL EXTERNAL COMPLETE FANLIGHT PCM PCM PCM CR328106 DOOR:RENEW BOARD TO LEDGED AND BRACED DOOR PCM PCM PCM CR328108 DOOR:RENEW LEDGE OR BRACE TO DOOR PCM PCM Doors - External - Repairs - PVCu PCM CR325101 DOOR:RENEW ANY BUTT HINGE TO PVCU PCM Door:Renew any butt hinge to PVCu door. PCM CR325103 DOOR:OVERHAUL MULTIPOINT LOCK TO PVCU PCM Door:Overhaul and lubricate multi-point door locking system to PVCu door. PCM CR325105 DOOR:RENEW MULTIPOINT LOCK TO PVCU PCM PCM PCM CR325107 DOOR:ADJUST LOCK TO PVCU PCM PCM PCM CR325109 DOOR:LOCK CYLINDER TO PVCU PCM PCM PCM CR325111 DOOR:RENEW LOCK CATCH OR KEEP TO PVCU PCM PCM PCM CR325113 DOOR:REPAIR HANDLES TO PVCU Door:Overhaul external door and frame complete, remove all ironmongery, piece out door, frame and architraves where ironmongery removed make good any damage, defects to timber, resecure architraves if loose, rehang door on one and a half pair of butt hinges, ease and adjust, prepare door for redecoration, and remove waste and debris. Door:Overhaul external door and frame with fanlight complete, remove all ironmongery, piece out door, frame, and architraves where ironmongery removed make good any damage, defects to timber, resecure glazing beads, and architraves if loose, rehang door on one and a half pair of butt hinges, ease and adjust, reglaze fanlight as necessary to BS 6262, prepare door for redecoration, and remove waste and debris. Door:Renew 114x25mm preservative treated softwood tongued and grooved board to ledged and braced door and prepare for redecoration, and remove waste and debris. Door:Renew 105x20mm preservative treated softwood ledge or brace to ledged and braced door, and prepare for redecoration, and remove waste and debris. Door:Renew any defective or broken multi- point door locking system complete to PVCu door, adapt keep if necessary, including remove existing, test and leave in working proper working order and remove waste and debris. Door:Carefully remove existing PVCu door lock, ease and adjust door in order to ensure correct working, refix existing lock. Door:Renew any type of lock cylinder to PVCu door including drilling out old cylinder, replacing with new matching cylinder complete with 2 No. keys, make good, test and leave in proper working order and remove waste and debris. Door:Renew any door catch or keep to PVCu door including all adjustment and making good necessary. PCM PCM Door Frames - External - High Performance PCM CR341201 FRAME:RENEW EXTERNAL PERMADOR PCM PCM PCM CR341203 FRAME:RENEW PERMADOR FRAME WITH CILL COMPLETE PCM PCM PCM CR341205 FRAME:RENEW PERMADOR FANLIGHT COMPLETE PCM PCM PCM CR341207 FRAME:RENEW PERMADOR FANLIGHT CILL PCM PCM PCM Door Frames - Water Bars PCM CR341701 WATERBAR:RENEW PCM PCM PCM CR341705 WATERBAR:REFIX WATERBAR PCM PCM Door and Window Frames - Draughtproofing Strips and Sections PCM CR341901 WEATHERSTRIP:FIX AA TO DOOR AND FRAME PCM Frame:Renew external door frame with softwood door frame, rebated and with fanlight over, to suit any size single door, remove existing door and set aside, remove existing frame and bed new frame in mortar, plugged and screwed to brickwork and point with sealant, rehang door including ease and adjust, refix lock keep including housing out, make good all works disturbed including refix or renew internal beads, architraves etc., glaze to fanlight and decorate to match existing internally and prepare for redecoration externally, and remove waste and debris. Frame:Renew external door frame with rebated proprietary high performance door frame to suit any size single door, take out existing frame and bed new frame in cement mortar, plugged and screwed to brickwork and pointed with sealant, make good all works disturbed including refix or renew any internal beads, architraves etc., and remove waste and debris. Frame:Renew external door frame with rebated proprietary high performance door frame with cill to suit any size single door, take out existing frame and bed new frame in cement mortar, plugged and screwed to brickwork and pointed with sealant, make good all works disturbed including refix or renew any internal beads architraves etc., and remove waste and debris. Frame:Renew external door frame with rebated proprietary high performance door frame and fanlight over, to suit any size single door, remove existing frame and bed new frame in mortar, plugged and screwed to brickwork and pointed with sealant, make good all works disturbed including refix or renew any internal beads, architraves etc., glaze to fanlight and remove waste and debris. Frame:Renew external door frame with rebated proprietary high performance door frame with cill and fanlight to suit any size single door, remove existing frame and bed new frame in mortar, plugged and screwed to brickwork and pointed with sealant, make good all works disturbed including refix or renew any internal beads, architraves etc., and remove waste and debris. Waterbar:Renew ne 914mm long proprietary waterbar screwed to timber or concrete including plugging and bedded in sealant. Waterbar:Lift existing proprietary waterbar, clean and refix, screw to timber and bed in sealant. Weatherstrip:Supply and fix anodised aluminium proprietary weatherstrip to door and frame. PCM PCM CR341903 WEATHERSTRIP:RENEW REBATED TO DOOR PCM Weatherstrip:Renew proprietary rebated weatherstrip to edge of timber door. PCM PCM CR341905 CILL:RENEW OR SUPPLY AND FIX STORMGUARD CILL PCM PCM PCM CR341921 DRAUGHTPROOF:RENEW FOAM STRIP PCM PCM PCM CR341923 DRAUGHTPROOF:RENEW PLASTIC BRUSH TYPE PCM PCM Door Frame - Repairs - Timber PCM CR342302 FRAME:RENEW CLOSING EXTERNAL JAMB PCM PCM PCM CR342304 FRAME:RENEW HANGING EXTERNAL JAMB PCM PCM PCM CR342306 FRAME:SPLICE EXTERNAL REPAIR NE 1.0M PCM PCM PCM CR342309 FRAME:REFIX LOOSE EXTERNAL FRAME PCM PCM PCM CR342316 FRAME:RENEW HARDWOOD CILL Cill:Renew or supply and fix Stormguard or other equal and approved stormproof cill to existing cill including remove/rehang door, fix.new cill including adapting door and existing cill as necessary and make good. Draughtproof:Renew existing or supply and fix new vinyl sheathed compressible polyurethane foam draught strip with adhesive backing to any door or window at any level. Draughtproof:Renew existing or supply and fix new brush or pile type draught excluder with rigid PVC carrier, to any door or window at any level including fixing with pins to timber. Frame:Renew closing jamb of single external door frame, joint new any size and profile, preservative treated softwood door frame, splayed joint to head, bedded in cement mortar, plugged and screwed to brickwork, including take off and refix stop and architrave, take off and refix lock and keep including housing out, decorate to match existing internally and prepare for redecoration externally, make good all works disturbed including renew sealant and remove waste and debris. Frame:Renew hanging jamb of single external door frame, remove existing door and set aside, cut out frame, joint new any size and profile, preservative treated softwood door frame to head frame bedded in cement mortar, plugged and screwed to brickwork including take off and refix stop and architraves, cut out housing for butts and rehang door, ease and adjust, decorate to match existing internally and prepare for redecoration externally, make good all works disturbed including renew sealant and remove waste and debris. Frame:Cut out and splice new piece ne 1.00m long into external door frame, including remove and rehang door, remove and refix keep as necessary, ease and adjust and make good butt recesses in frame, point with sealant, and decorate to match existing internally and prepare for redecoration externally, and remove waste and debris. Frame:Remove and refix loose external door frame, including remove and refix door and one set of architraves, touch up decorations and renew sealant and remove waste and debris PCM PCM Door Stops - Softwood PCM CR342503 STOP:RENEW DOOR STOP SET PCM PCM PCM CR342505 STOP:REFIX LOOSE DOOR SET PCM Stop:Refix any loose door stop set to door frame. PCM PCM CR342507 STOP:RENEW OR SUPPLY 25X50MM FIRE DOOR STOP PCM PCM PCM Doors - Garage - Matchboard - Softwood PCM CR345202 DOOR:RENEW PAIR L AND B TO GARAGE PCM PCM CR345204 DOOR:EASE ADJUST GARAGE INCLUDING REMOVE PCM PCM Doors - Garage - Renewals - Up and Over Metal PCM CR345402 GARAGE DOOR:RENEW METAL UP AND OVER PCM PCM PCM Doors - Garage - Repairs - Up and Over Metal PCM PCM CR345602 GARAGE DOOR:REMOVE AND REFIX UP AND OVER PCM PCM PCM CR345604 GARAGE DOOR:REPAIR UP AND OVER METAL PCM PCM Frame:Renew any size hardwood cill to door frame including remove old cill, remove and rehang door, fix new cill bedded in cement mortar including new water bar, make good all finishes disturbed, decorate internally and prepare for redecoration externally, and remove waste and debris. Stop:Renew any size up to 25x50mm planted softwood door stop set to door frame and prepare for redecoration, and remove waste and debris. Stop:Renew or supply any door stop with 25x50mm softwood door stop set to fire check door, glued, screwed in accordance with BS459 Part 2 to door frame and prepare for redecoration. 7.5          Garage Doors and Frames Door:Renew garage doors with new pair of 45mm softwood preservative treated ledged, braced and matchboarded doors to suit size of existing opening with 169x20mm ledges and 106 x 20mm braces covered on face with 20mm tongued, grooved and 'V' jointed boarding and hang each leaf on one pair of 450mmm galvanised tee hinges, transfer existing lock and bolts, make good and prepare for redecoration, and remove waste and debris. Door:Ease and adjust pair of garage doors, each hung on pair of tee hinges, including remove and rehang doors, make good to frame and prepare for redecoration, and remove waste and debris. Door:Renew any garage door with pre-primed metal up and over garage door, overall size ne 2438x2055mm complete with all ironmongery and hanging to existing frame, make good to all works disturbed and prepare for redecoration, and remove waste and debris. Garage Door:Take down and rehang metal up and over garage door, ease and adjust operating mechanism and leave operational, and prepare for redecoration, and remove waste and debris. Garage Door:Repair any metal up and over garage door incl remove fittings and door, straighten/repair dents and holes, rehang door, fittings and ease, and prepare for redecoration, and remove waste and debris. PCM PCM PCM CR386007 WINDOWBOARD:REFIX LOOSE PCM PCM PCM CR386009 WINDOWBOARD:RENEW PVCU PCM PCM PCM CR386111 WINDOW:PROVIDE PVCu COVER FILLET PCM PCM PCM Butts, Hinges etc. PCM CR390101 HINGES:RENEW 63MM STORMPROOF PCM PCM PCM CR390105 HINGES:RENEW PAIR OF FRICTION PIVOTS PCM PCM PCM CR390107 HINGES:RENEW STEEL BUTT HINGES PCM PCM PCM CR390109 HINGES:RENEW BRASS BUTT HINGES PCM PCM PCM CR390111 HINGES:RENEW PAIR TEE HINGES PCM PCM PCM CR390113 HINGES:RENEW PAIR OF 50MM BUTT HINGES PCM PCM PCM Sliding Sash Fittings PCM CR390301 FASTENER:RENEW ANY TYPE OF SASH FASTENER PCM Fastener:Renew/supply and fix new sash fastener including make good. PCM PCM CR390307 LIFT:RENEW SASH LIFT PCM Lift:Renew/supply and fix new sash lift. PCM PCM CR390309 BOLT:RENEW SASH BOLT PCM Windowboard:Renew ne 25x300mm hardwood windowboard, plugged, screwed and pellated to brickwork, , make good plasterwork and prepare to decorate. Windowboard:Refix any size or type of loose cillboard to window including removing if necessary, make good plasterwork. Windowboard:Renew existing with PVCu ne 25x300mm windowboard fixed with approved adhesive or other approved concealed fixing method to brickwork, make good plasterwork. Window:Provide 19mm PVCu quadrant cover fillet fixed with approved adhesive or other approved concealed fixing method internally around windows make good plasterwork. 7.6          Ironmongery Hinges:Renew pair of 63mm anodised steel stormproof hinges including remove and rehang casement. Hinges:Renew pair of friction hinges to pivot window including remove and refix casement. Hinges:Renew ne 1.5 pairs 100mm mild steel butt hinges, ease and adjust door, make good to recesses in frame. Hinges:Renew ne 1.5 pairs 100mm brass butt hinges, ease and adjust door, make good to recesses in frame. Hinges:Renew pair of 300mm galvanised tee hinges, ease and adjust door, make good to frame. Hinges:Take off cupboard door and set aside, remove hinges and renew with pair of 50mm butt hinges, rehang door, ease and adjust. Bolt:Renew/supply and fix new lockable sash bolt to centre rail of sliding sash timber windows including make good and, hand key to Tenant. PCM PCM CR390311 LOCK:RENEW PAIR OF SASH LOCKS PCM PCM PCM CR390313 SASH PINS:RENEW PAIR SASH PINS PCM PCM Door Closers PCM PCM CR390501 CLOSER:RENEW LIGHT DUTY OVERHEAD PCM PCM PCM CR390503 CLOSER:RENEW HEAVY DUTY OVERHEAD PCM PCM PCM CR390505 CLOSER:RENEW OR SUPPLY PERKO TYPE PCM PCM PCM CR390507 CLOSER:EASE AND ADJUST PCM Closer:Ease and adjust any type door closer. PCM Locks PCM CR390901 RIMLOCK:RENEW COMPLETE PCM PCM PCM CR390903 LOCK:RENEW MORTICE COMPLETE PCM PCM PCM CR390909 LOCK:RENEW MORTICE DEADLOCK PCM PCM PCM CR390911 LOCK:RENEW 5L MORTICE COMPLETE PCM PCM PCM CR390915 LOCK:RENEW 5L MORTICE DEADLOCK PCM PCM PCM CR390917 LOCK:OVERHAUL ANY LOCK COMPLETE PCM Lock:Renew or supply and fix new pair of lockable sash locks to restrict opening of sliding sash timber windows, including make good and hand key to Tenant. Sash Pins:Renew or supply and fix new pair of dual sash pins to centre rail of sliding sash timber windows, including make good and hand key to Tenant. Closer:Renew approved light duty overhead door closer screwed to door and frame. Closer:Renewapproved heavy duty overhead door screwed to door and frame. Closer:Renew or supply and fix Perko type concealed door closer screwed to door and frame. Rimlock:Renew rimlock, keep and set of rimlock furniture, including altering door as necessary for new lock and housing out existing frame as necessary and provide two new keys. Lock:Renew mortice lock, keep and set of anodised aluminium lever handle furniture including altering door as necessary for new lock and provide two new keys. Lock:Renew mortice deadlock, keep and set of escutcheons including altering door as necessary for new lock and provide two new keys. Lock:Renew 5 lever mortice lock, keep and set of anodised aluminium lever handle furniture including altering door as necessary for new lock and provide two new keys. Lock:Renew 5 lever mortice deadlock, keep and set of escutcheons including altering door as necessary for new lock and provide two new keys. Lock:Remove any type of lock and furniture, dismantle, overhaul, repair, oil and assemble and refix to door. PCM Latches PCM CR391101 LATCH:RENEW MORTICE LATCH COMPLETE PCM PCM PCM CR391107 LATCH:OVERHAUL LATCH AND FURNITURE PCM PCM Cylinder Night Latches PCM CR391301 NIGHTLATCH:RENEW COMPLETE PCM PCM CR391305 NIGHTLATCH:RENEW CYLINDER BARREL PCM Nightlatch:Renew cylinder barrel to night latch and provide two new keys. PCM PCM CR391307 NIGHTLATCH:RENEW SUITED CYLINDER BARREL PCM Nightlatch:Renew suited cylinder to nightlatch and provide two keys. PCM PCM CR391309 NIGHTLATCH:OVERHAUL COMPLETE PCM PCM Bolts, Security Bolts, Panic Bolts and Padlocks PCM CR391701 BOLT:RENEW NE 250MM PADBOLT PCM Bolt:Renew ne 250mm galvanised approved padbolt. PCM PCM CR391703 BOLT:RENEW 200MM TOWER BOLT PCM Bolt:Renew 200mm tower bolt and keep. PCM PCM CR391705 BOLT:RENEW NE 150MM BARREL BOLT PCM Bolt:Renew ne 150mm barrel bolt and keep. PCM PCM CR391707 BOLT:RENEW INDICATOR BOLT PCM Bolt:Renew 175mm SAA bathroom indicator bolt and keep. PCM PCM CR391709 BOLT:RENEW MORTICE SECURITY BOLT PCM PCM CR391711 BOLT:RENEW SINGLE PANIC BOLT PCM Bolt:Renew approved SAA panic bolt and keep to single door. PCM PCM CR391713 BOLT:RENEW FIRE SECURITY BOLT PCM PCM PCM CR391715 BOLT:RENEW GLASS TO FIRE SECURITY BOLT PCM Bolt:Renew glass tube to fire security bolt including reset. PCM PCM CR391719 BOLT AND KEEP:REMOVE EASE AND REFIX PCM Latch:Renew mortice latch, keep and set of anodised aluminium lever handle furniture including altering door as necessary for new latch. Latch:Remove mortice latch and furniture, dismantle, overhaul, repair, oil and assemble and refix to door. Nightlatch:Renew cylinder rim night latch, keep and pull handle, including altering door as necessary for new latch and provide two new keys. Nightlatch:Remove any type of cylinder nightlatch dismantle, overhaul, repair, oil and assemble and refix to door. Bolt:Renew or supply and fix new mortice security bolt with key operation and keep Bolt:Renew fire security bolt, surface fixed to emergency exit doors comprising metal bolt held extended by clear glass tube retained by padlock including keep, hammer and chain. Bolt and Keep:Remove barrel bolt or bolt keep, oil and ease as necessary and refix bolt and or bolt keep in new position.
Docsity logo



Copyright © 2024 Ladybird Srl - Via Leonardo da Vinci 16, 10126, Torino, Italy - VAT 10816460017 - All rights reserved