OADICENTERS
- ENABLED
AS
SA E Er o
INIA
AS
1- INDOOR TYPE
Standard Load Center (Type LD) >
IEC Compliant Distribution Board E
IEC Standards (IEC 60439-3 And IEC 60529) [CB 5
a Figure 5
El Single-Phase LC 63 A With Isolator Main
AAN
H h | ww D H h[|wi]|wD
4 43-1104063 | 273 | 243 | 280 | 250 | 95 | 43-1104063S | 248 | 243 | 255 | 250 | 95
6 43-1106063 | 309 | 279 | 280 | 250 | 95 | 43-1106063S | 284 | 279 | 255 | 250 | 95
8 43-1108063 | 345 | 315 | 280 | 250 | 95 | 43-1108063S | 320 | 315 | 255 | 250 | 95
10 43-1110063 | 381 | 351 | 280 | 250 | 95 | 43-1110063S | 356 | 351 | 255 | 250 | 95
12 43-1112063 | 417 | 387 | 280 | 250 | 95 | 43-1112063S | 392 | 387 | 255 | 250 | 95
14 43-1114063 | 453 | 423 | 280 | 250 | 95 | 43-1114063S | 428 | 423 | 255 | 250 | 95
16 43-1116063 | 489 | 459 | 280 | 250 | 95 | 43-1116063S | 464 | 459 | 255 | 250 | 95
Main Breaker: 63A
Change last four digits for required ratings and mounting
For example:
43-1112063_ Represents load center 12 way with 63A main flush type
43-1112063S Represents load center 12 way with 63A main surface type
O Single-Phase LC 100 A With Isolator Main
ANA IN a da
4 43-1104100 | 273 | 243 | 280 | 250 | 95 | 43-11041008 |248| 243 | 255 | 250 | 95
6 43-1106100 | 309 | 279 | 280 | 250 | 95 | 43-11061008 |284| 279 | 255 | 250 | 95
8 43-1108100 | 345 | 315 | 280 | 250 | 95 | 43-1108100S |320| 315 | 255 | 250 | 95
10 43-1110100 | 381 | 351 | 280 | 250 | 95 | 43-11101008 |356| 351 | 255 | 250 | 95
12 43-1112100 | 417 | 387 | 280 | 250 | 95 | 43-11121008 |392| 387 | 255 | 250 | 95 a .-
14 43-1114100 | 453 | 423 | 280 | 250 | 95 | 43-11141008 |428| 423 | 255 | 250 | 95
16 43-1116100 | 489 | 459 | 280 | 250 | 95 | 43-1116100S |464| 459 | 255 | 250 | 95
Main Breaker: 100A
Change last four digits for required ratings and mounting
For example:
43-1112100 Represents load center 12 way with 100A main flush type
43-1112100S Represents load center 12 way with 100A main surface type
Figure 8
ET. Two-Phase LC 63 A With Isolator Main
(DANA AIN
4 43-0404063 | 273 | 243 | 280 | 250 | 95 | 43-0404063S |248| 243 | 255 | 250 | 95
6 43-0406063 | 309 | 279 | 280 | 250 | 95 | 43-0406063S | 284 | 279 | 255 | 250 | 95
8 43-0408063 | 345 | 315 | 280 | 250 | 95 | 43-0408063S |320| 315 | 255 | 250 | 95
10 43-0410063 | 381 | 351 | 280 | 250 | 95 | 43-0410063S |356| 351 | 255 | 250 | 95
12 43-0412063 | 417 | 387 | 280 | 250 | 95 | 43-0412063S |392| 387 | 255 | 250 | 95
14 43-0414063 | 453 | 423 | 280 | 250 | 95 | 43-0414063S |428| 423 | 255 | 250 | 95
16 43-0416063 | 489 | 459 | 280 | 250 | 95 | 43-0416063S |464| 459 | 255 | 250 | 95 Figure 9
Main Breaker: 63A
Change last four digits for required ratings and mounting
For example:
43-0412063 — Represents load center 12 way with 63A main flush type
43-0412063S Represents load center 12 way with 63A main surface type
El. Two-Phase LC 100 A With Isolator Main
(AA
4 43-04100 | 273| 243 | 280 | 250 | 95 | 43-04041008 | 248| 243 | 255 | 250 | 95
6 43-06100 | 309 | 279 | 280 | 250 | 95 | 43-0406100S | 284| 279 | 255 | 250 | 95 l
8 43-08100 | 345 | 315 | 280 | 250 | 95 | 43-0408100S | 320| 315 | 255 | 250 | 95 l E
10 43-0410100 | 381 | 351 | 280 | 250 | 95 | 43-04101008 | 356| 351 | 255 | 250 | 95
12 43-0412100 | 417 | 387 | 280 | 250 | 95 | 43-0412100S | 392| 387 | 255 | 250 | 95 a !
14 43-0414100 | 453 | 423 | 280 | 250 | 95 | 43-0414100S | 428| 423 | 255 | 250 | 95 E E
16 43-0416100 | 489 | 459 | 280 | 250 | 95 | 43-04161008 | 464| 459 | 255 | 250 | 95
Figure 10
Main Breaker: 100A
Change last four digits for required ratings and mounting
For example:
43-0412100 Represents load center 12 way with 100A main flush type
43-04121005S Represents load center 12 way with 100A main surface type
ET” Three-Phase LC 100 A With Isolator Main
AAA EIN A
12 4 43-12100 | 582 | 550 | 407 | 375 | 105 | 43-121008 | 582 | 550 | 407 | 375 | 105
18 6 43-18100 | 637 | 605 | 407 | 375 | 105 | 43-181008 | 637 | 605 | 407 | 375 | 105
24 8 43-24100 | 692 | 660 | 407 | 375 | 105 | 43-241008 | 692 | 660 | 407 | 375 | 105
30 10 43-30100 | 747 | 715 | 407 | 375 | 105 | 43-301008 |747 | 715 | 407 | 375 | 105
36 12 43-36100 | 802 | 770 | 407 | 375 | 105 | 43-361008 |802 | 770 | 407 | 375 | 105 Ú
42 14 43-42100_| 857 | 825 | 407 | 375 | 105 | 43-421008_|857 | 825 | 407 | 375 |105 5
Main Breaker: 1004
Change last four digits for required ratings and mounting
For example:
43-30100 Represents load center 30 way with 100A main flush type
43-301008 Represents load center 30 way with 100A main surface type
Figure 11
ET. Three-Phase LC With MCCB Main Rating From 30-100 AF
(AAA AIN A
12 4 43-112100 | 582 | 550 | 407 | 375 | 105 | 43-L121008 | 582 | 550 | 407 | 375 | 105
18 6 43-L18100 | 637 | 605 | 407 | 375 | 105 | 43-L181008 | 637 | 605 | 407 | 375 | 105
24 8 43-124100 | 692 | 660 | 407 | 375 | 105 | 43-L241008 | 692 | 660 | 407 | 375 | 105
30 10 43-L30100 | 747 | 715 | 407 | 375 | 105 | 43-L301008 | 747 | 715 | 407 | 375 | 105
36 12 43-L36100 | 802 | 770 | 407 | 375 | 105 | 43-L36100S | 802 | 770 | 407 | 375 | 105
42 14 43-142100 | 857 | 825 | 407 | 375 | 105 | 43-L42100S | 857 | 825 | 407 | 375 | 105
Main Breaker: Ranges from 30-100A
Change last four digits for required ratings and mounting Figure 12
For example:
43-112060 Represents load center 12 way with 60A main flush type
43-112100S Represents load center 12 way with 100A main surface type
E Three-Phase LC With MCCB Main Rating From 125-225 AF
(AIN A 3
12 4 43-12225 | 692 | 660 | 407 | 375 | 105 | 43-12225S | 692 | 660 | 407 | 375 | 105
18 6 43-18225 | 747 | 715 | 407 | 375 | 105 | 43-18225S | 747 | 715 | 407 | 375 | 105
24 8 43-24225 | 802 | 770 | 407 | 375 | 105 | 43-24225S | 802 | 770 | 407 | 375 | 105
30 10 43-30225 | 857 | 825 | 407 | 375 | 105 | 43-30225S | 857 | 825 | 407 | 375 | 105
36 12 43-36225 | 912 | 880 | 407 | 375 | 105 | 43-36225S | 912 | 880 | 407 | 375 | 105
42 14 43-42225 | 967 | 935 | 407 | 375 | 105 | 43-42225S | 967 | 935 | 407 | 375 | 105
48 16 43-48225 |1022| 990 | 407 | 375 | 105 | 43-48225S |1022| 990 | 407 | 375 | 105
Figure 13
Main Breaker: Ranges from 125-2254
Change last four digits for required ratings and mounting
For example:
43-42125 Represents load center 42 way with 125A main flush type
43-422258 Represents load center 42 way with 225A main surface type
El Three-Phase 2 Section Load Center With 3 Pole Main Isolator or MCB
And Both Sections Protected By 2 Nos. of 4 Pole ELCBs
ORDERING NUMBER AND TYPE
H|h|wfwjoD H|h|wi|wjpDb
6+6 | 2+2 |48-106061002020 |712| 682 | 373 | 343 [105 | 48-106061002020S | 696 | 682 | 357 | 343 [105
12+6 | 4+2 |48-112061002020 |766|736 | 373 | 343 |105| 48-112061002020S [750 |736 | 357 | 343 [105
12+12 | 4+4 |48-112121002020 | 820 | 790 | 373 | 343 |105 | 48-112121002020S | 804 | 790 | 357 | 343 [105
18+12 | 6+4 |48-118121002020 | 874 | 844 | 373 | 343 |105 | 48-118121002020S | 858 | 844 | 357 | 343 [105
18+18 | 6+6 |48-118181002020 | 920| 890 | 373 | 343 |105 | 48-118181002020S | 904 | 890 | 357 | 343 [105
24+18 | 8+6 |48-124181002020 | 974 | 944 | 373 | 343 |105| 48-1241810020208 | 958 | 944 | 357 | 343 |105
Figure 19
El Three-Phase 2 Section Load Center With 3 Pole Main MCCB
And Both Sections Protected By 2 Nos. of 4 Pole ELCBs
AA IN
II o) H|h|wWj|w]Db
6+6 | 2+2 | 48-LO6061002020 | 906 | 876 | 430 | 400 |105 | 48-LO6061002020S | 890 | 876 | 414 | 400 [105
12+6 | 4+2 | 48-112061002020 | 960 | 930 | 430 | 400 [105 | 48-1120610020205 | 944 | 930 | 414 | 400 [105
12+12| 4+4 | 48-112121002020 |1014| 984 | 430 | 400 [105 | 48-1121210020208 | 998 | 984 | 414 | 400 [105
18+12| 6+4 | 48-118121002020 |1068|1038| 430 | 400 [105 | 48-1181210020208 [1052 1038| 414 | 400 [105
18+18| 6+6 | 48-118181002020 |1122|1092|430 | 400 [105 | 48-1181810020208 [1106] 1092| 414 | 400 [105
24+18| 8+6 | 48-24181002020 |1176|1146| 430 | 400 [105 | 48-.241810020208 |1160/1146| 414 | 400 |105
48 - L 060610020 20 S
1 Type Surface * MAIN BREAKER RATING ** ELCB RATING Figure 20
ELCB Rating Section-2
CODE RATING cope [raro
** ELCB Rating Section-1_ [963-100 [| 63, TOA ISOLATOR Y. 20 ET
* Main Breaker Rating_ | 030-100 || FOR 30, 40,50,60,70,100A MCB T" 30 100A 30mA
No, Of Ways Section-2_ | 030-100 || FOR 30,. ,100A MCCB *L* 40 63A 100mA
No, Of Ways Section-1_ [ 125-225 |[ for 125,150,175,200,225A MCc8 1] [50 ][ 1004 100mA
EL ForMICOB, “Y ForMCB, Y Forlslalor_ please Select Your Product As Mentioned Above
2- OUTDOOR TYPE
Figure 21
ET Three-Phase LC 100A With Isolator Main
AIN la e
12 4 43-WP12100 515 350 160
18 6 43-WP18100 592 350 160
24 8 43-WP24100 668 | 350 | 160 .
30 10 43-WP30100 745 350 160
36 12 43-WP36100 821 350 160
42 14 43-WP42100 898 350 160
Main Breaker: 1004 .
Change last three digits for required ratings Figure 22
For example:
43-WP42100 Represents load center 42 way with 100A main
43-WP24100 Represents load center 24 way with 100A main
[ET Three-Phase LC 100A With MCCB Main Rating From 30-100AF
NAO SN da
12 4 43-WPL12100 515 350 160 |
18 6 43-WPL18100 592 350 160
24 8 43-WPL24100 668 350 160
30 10 43-WPL30100 745 350 160
36 12 43-WPL36100 821 350 160
42 14 43-WPL42100 898 350 160 ]
Main Breaker: Ranges from 30-100 —
Change last three digits for required ratings Figure 23
For example:
43-WP18030 Represents load center 18 way with 30A main
43-WP18100 Represents load center 18 way with 100A main
Er Three-Phase LC With MCCB Main Rating From 125-225AF
ORDERING NUMBER AND TYPE .
H w D
12 4 43-WPL12225 615 | 350 | 160 Ms
18 6 43-WPL18225 692 | 350 | 160
24 8 43-WPL24225 768 | 350 | 160
30 10 43-WPL30225 845 | 350 | 160
36 12 43-WPL36225 921 350 | 160
42 14 43-WPL42225 998 | 350 | 160 tr
48 16 43-WPLA48225 1074 | 350 | 160
Main Breaker: Ranges from 125-225A De
Change last three digits for required ratings Figure 24
For example:
43-WPL42125 Represents load center 42 way with 125A main
43-WPL42225 Represents load center 42 way with 225A main
e LD KNOCKOUTS
LD 3PH 100A MAIN 12W-42W
A-019/025 DOUBLE KNOCKOUT - 18 Nos.
B-035/043.5 DOUBLEKNOCKOUT -6 Nos.
C-6623/028/033 TRIPLEKNOCKOUT —-4 Nos.
D-44/050/062 TRIPLEKNOCKOUT -6 Nos,
E- WALL MOUNTING EMBOSS WITH KEY HOLE-4Nos.
Notes:
All dimension are in mm
The details in this drawing indicate dimensions and knockout
positions for one alfanar Load Center. Knockout details
for other Load Center types, shown in this catalogue, are
available on request
Figure 25
eo TESTING
All alfanar load centers type (LD) are type tested for complete sequence as per international standards.
Each of our products undergo strict quality control check and is routinely checked for:
PDOSIUACOS IE OS
SARA AOS AUS EEE EN
LETS ¿To ensure high insulation resistance
HTRAL REGION PROJECTS DIVISION
—
W REGIONS PROJECTS DEPARTMENT
S UNIT
alfanar products are approved by.
SEC
Saudi Electric Company
Saudi Aramco
Saudi Arabian Oil Company
SABIC
Saudi Basic Industries Corporation
Royal Commission For Jubail and Yanbu
SASO
Saudi Arabian Standards Organization
Several Ministries, Universities and Governmental
Organizations In Saudi Arabia
Abu Dhabi Water and Electricity Board
Ministry Of Electricity, Bahrain
State Electricity Board, Qatar
Public Electricity Corporation-
Ministry Of Electricity, Yemen
OUR OBJECTIVE
WE REACH EXACTING
STANDARDS IN THE
SAFETY AND
DISTRIBUTION OF
POWER AND GO WELL
BEYOND A CUSTOMER'S
EXPECTATIONS.
THIS IS DONE BY
FOCUSING OUR
TECHNOLOGY AND
EXPERTISE ON THE
ULTIMATE REWARD
WE CAN GET, COMPLETE
SATISFACTION OF
OUR CUSTOMERS.
as ara MATES
POST BOX PO. 15874,
QUALITY POLICY
The Quality Policy of alfanar ¡s, to:
+ Provide products conforming to governing standards and of
consistent quality
+ Excel in all our operations to achieve customers? satisfaction
for products and services through continual improvement
+ Develop and maintain a motivated team of competent employees
and vendors
+ Redefine and execute new processes/systems that meet market
requirements.
alfanar PRODUCTS
MEANS
+ Junction Boxes
MIGAS
+ Stainless Steel Enclosures NEMA-4x
Telephone Enclosures
(AGRARIAS
ENS NOTES
Modular Enclosures
AO
NEMA Type LA Load Centers
ATRIO A
Split Busbar Units Type LAS/LDS Load Centers
PAE OOO
NAO
ASIA IAS
OOOO
Motor Control Centers
IAS IES
NIE AAA El
ESTI
Control and Automation Panels
Relay and Control Panels
Medium Voltage Switchgears
SOON EAS
IONES
85KA - 1 sec Short Circuit Withstand
NOE NAM
4s improvement af alfanar
NAT 7
K.S.A. Toll Free: 800 124 1333 catalogue may chang
AA All lote 5 IS