Hydraulic Ram Pump: Historical Overview and Modern Application, Tesine universitarie di Meccanica dei Fluidi

Mechanical Engineering DesignPump SystemsHydraulicsFluid Mechanics

An in-depth analysis of the design and construction of a hydraulic ram pump, a historical overview of its development, and its modern applications. The author, shuaibu ndache mohammed, discusses the principles of operation, the components of the pump, and the calculation of design parameters. The document also includes the results of a specific pump design and the sequences of the hydraulic ram operation.

Cosa imparerai

  • How is the volumetric discharge calculated for a hydraulic ram pump?
  • What is a hydraulic ram pump and how does it work?
  • What is the Darcy-Wersbach formula and how is it used to evaluate loss in head for fluid flow in pipes?
  • What are the main components of a hydraulic ram pump?
  • What are the sequences of operation for a hydraulic ram pump?

Tipologia: Tesine universitarie

2018/2019

Caricato il 09/11/2019

Thymisson.Paixao
Thymisson.Paixao 🇧🇷

10 documenti

1 / 12

Toggle sidebar

Documenti correlati


Anteprima parziale del testo

Scarica Hydraulic Ram Pump: Historical Overview and Modern Application e più Tesine universitarie in PDF di Meccanica dei Fluidi solo su Docsity! Leonardo Electronic Journal of Practices and Technologies ISSN 1583-1078 Issue 11, July-December 2007 p. 59-70 Design and Construction of a Hydraulic Ram Pump Shuaibu Ndache MOHAMMED Department of Mechanical Engineering, Federal University of Technology, Minna, Nigeria shuaibu_mohammed@yahoo.com Abstract The Design and Fabrication of a Hydraulic Ram Pump (Hydram) is undertaken. It is meant to lift water from a depth of 2m below the surface with no other external energy source required. Based on the design the volume flow rate in the derived pipe was 4.5238 × 10-5 m3/s (2.7 l/min), Power was 1.273 kW which results in an efficiency of 57.3%. The overall cost of fabrication of this hydram shows that the pump is relatively cheaper than the existing pumps. Keywords Hydram; Pump; Volume Flow Rate; Power; Efficiency; Impulse Valve; Delivery Valve. Introduction The hydraulic Ram pump or hydram is a complete automatic device that uses the energy in the flowing water such as spring, stream or river to pump part of the water to a height above that of the source. With a continuous flow of water a hydram operates continuously with no external energy source. A hydram is a structurally simple unit consisting of two moving parts. These are the impulse valve (or waste valve) and the delivery (check) valve. The unit also consists of an air chamber and an air valve. The operation of a hydram is intermittent due to the cyclic opening and cloning of the waste and delivery values. The closure of the waste valve creates a high http://lejpt.academicdirect.org 59 Design and Construction of a Hydraulic Ram Pum Shuaibu N. MOHAMMED pressure rise in the drive pipe. An air chamber is required to transform the high intermittent pumped flows into a continuous stream of flow. The air valves allow air into the hydram to replace the air absorbed by the water due to the high pressure and mixing in the air chamber. Pumps are among the oldest of the machines. They were used in ancient Egypt, China, India, Greece and Rome. Today, pumps are the second most commonly used kind of industrial equipment after the electric motors (Working, 1996). The first pumps were force pumps and it is interesting that the earliest known example, a pump used by the Greeks in 300 B.C incorporated an air vessel. The use of this device was suspended in the middle-ages and revived in the 16th century when a German translation of the Greek work describing the pump was published. The earliest pump to be used was the hand pump. More advanced pumps were, however, known to the Romans, as shown by the double cylinder force pump now preserved in the British museum, but their use was apparently lost in this century at the end of the Roman Empire. In Roman times, the first reciprocating pump appeared (250-0 BC) and this remained the main pump type in use for several centuries, operated by hand, animal, water or wind power, mechanical skill developed, and metals came more into use, but the limiting factor with all these older pumps was the relatively low power output which is delivered by them. The highest power developed by wind miles or water wheel were of the order of 10 horsepower (hp). The reciprocating pumps, which relied on suction, could only lift water slightly above 10 metres. The performance of known types of pumps continued to be improved upon and their range of applications extended. One of such is the peristaltic pump which was developed into a pump for handling slurries of high specific gravity on a cost effective basis. Similarly, the Archimedean screw pump was developed into giant sizes for lifting water to high elevations. It is reported that the first hydraulic ram pump was built by Whitehurst (1775), which operated manually by the opening and closing of the stopcock. This hydram was able to raise water to a height of 4.9m. The first automatic hydram was invented by Montgolfier in 1796 for raising water in his paper mill. His work was improved upon by pierce (1816), who designed the air or sniffer valve to introduce air into the air chamber and this hydram, which is 300 mm in diameter is reported to have pumped 1700l/min to a height of 48m. Easton and James (1820) were the first to produce hydrams in large scale for commercial purpose. Their rams were used for supplying water to large country houses, farms and village communities. 60 Leonardo Electronic Journal of Practices and Technologies ISSN 1583-1078 Issue 11, July-December 2007 p. 59-70 The Darcy–Wersbach formula is the basis of evaluating the loss in head for fluid flow in pipes and conduits and is given by ⎟⎟ ⎠ ⎞ ⎜⎜ ⎝ ⎛ = g2 V d LflossHeat 2 (5) where, g = acceleration due to gravity, L = length of the pipe, V= fluid velocity and d = pipe diameter. The velocity of fluid flow in the T–junction is given by T T A QV = (6) where Q = is the volumetric fluid discharge and AT = pipe x-sectional area at T-junction. Loss due to sudden enlargement at the T-junction is expressed as ( ) g2 VVH 2 Td LT − = (7) Other losses of head, as in pipe fittings are generally expressed as ⎟⎟ ⎠ ⎞ ⎜⎜ ⎝ ⎛ = g2 VKH 2 TL (8) Since the head (H) contributed to water acceleration in the driven pipe, this acceleration is given by ∑ ⎟ ⎠ ⎞ ⎜ ⎝ ⎛=⎟⎟ ⎠ ⎞ ⎜⎜ ⎝ ⎛ −⎟⎟ ⎠ ⎞ ⎜⎜ ⎝ ⎛ − dt dvx D L g2 VKx g2 V D LFxH 22 (9) The value of K and f can be found from standard reference handbooks/textbooks. Eventually this flow will accelerates enough to begin to close the waste valve this occurs when the drag and pressure in the water equal the weight of the waste value. The drag force given by equation g2 VxxxACf Tvdd ρ= (10) The force that accelerates the fluid is given by dt dvALxmaF ρ== (11) 63 Design and Construction of a Hydraulic Ram Pum Shuaibu N. MOHAMMED The pressure at point is obtained by divided the force F in Equation (11) by the area A. A FP3 = (12) The power required can k calculated using this expression gQhP ρ= (13) The efficiency of the hydram is given by xH)QwQ( QxhE + = (14) Results The calculated design parameters for the hydraulic ramp pump are done based on the following specifications of supply and delivery heads from a published manual on the hydraulic ram for pumping water by WATT [4]. Table 1 gives the values of the calculated parameters. Design Specifications: • Supply Head = 1.5m • Delivery Head = 2.87m Table1. Results of calculated parameters Parameters Values Drive pipe diameter Drive pipe length Speed of diaphragm Flow discharge in drive pipe Total head losses in the system Force on waste valve Pressure at waste valve Power developed by the hydram Hydraulic pump efficiency 25 mm 90 mm 96 beats/min 2.3 l/min 11.71 ×10-4m 7.2 N 3668 kN/m2 1.273 kW 57.3 % 64 Leonardo Electronic Journal of Practices and Technologies ISSN 1583-1078 Issue 11, July-December 2007 p. 59-70 Mode of Operation and Performance Evaluation Operation Principle The energy required to make a Ram lift water to a higher elevation comes from water falling downhill due to gravity. As in all other water powered devices, but unlike a water wheel or turbine, the ram uses the inertia of moving part rather than water pressure and operates in a cycle based on the following sequences. Sequence I Water from the source flow through the drive pipe (A) into the ram pump body, fills it and begins to exit through the waste or “impulse” valve (B). The check valve (C) remains in its normal closed positions by both the attached spring and water pressure in the tank (D) and the delivery pipe (E) (no water in the tank prior to start up). At this starting point there is no pressure in tank (D) and no water is being delivered through exit pipe (E) to the holding tank destination. See Figure 1. E D C B A Figure 1. Hydraulic Ram Sequence I 65 Design and Construction of a Hydraulic Ram Pum Shuaibu N. MOHAMMED Installation The installation of a hydram pump (see figure 5) is such that the cycle of its operation is dependent upon the length of the drive pipe. It is recommended that the pump should complete a cycle every 1.5 to 2 seconds. If a cycle is either too fast or too slow the output performance will suffer. Too fast of a cycle is a symptom of either a drive pipe being too short or the waste valve needing more weight. Too long of a cycle is caused by an excessively long drive pipe or so much weight on the waste valve that the column of water takes a longer time to overcome, causing it to close suddenly. This creates a momentary high pressure “Water hammer” that in turn force the check valve (C) to open allowing a high pressure “pulse” of water to enter the pressure tank (D). The air volume in the pressure tank is compressed causing water to begin flowing out of the delivery pipe (E) and at the same time closing the check valve (C) so as to prevent reverse flow. As the air volume in pressure tank (D) continues to expand, water is forced out of the delivery pipe (E) to the holding tank. Figure 5. A Typical Hydraulic Ram Installation Construction of the Hydram In designing an efficient hydraulic ram pump, the most basic decision involves the choice of materials. Beside their availability and cost which are always of primary consideration, materials are also chosen on the basis of their properties. Materials that prolong the life of pumps are largely suitable. Galvanized metal plates and pipes were used for the construction. Figure 6 shows the fabricated hydram pump system discussed in the study. 68 Leonardo Electronic Journal of Practices and Technologies ISSN 1583-1078 Issue 11, July-December 2007 p. 59-70 Figure 6. Fabricated Hydram Pump System Conclusion The present study is centred towards the development of a hydraulic ram pump that would conveniently alleviate the problem of water supply to the mass populace. Ideally, different combinations of the supply and delivery heads and flows, stroke length and weight of the impulse valve, length to diameter ratio of the drive pipe, volume of the air chamber and size of the snifter valve, etc. were tried to come up with an optimum size of a hydram pump presented in this study. References 1. Krol J., Automatic hydraulic Pump, PROC.I. MECH.E 1951, 164, p.103. 2. Calvert N. G., Hydraulic Ram, THE ENGINEER, 1967. 3. Molyneux F., The Hydraulic ram for Rival Water Supply, Fluid Handling, 1960, p. 274. 69 Design and Construction of a Hydraulic Ram Pum Shuaibu N. MOHAMMED 4. Watt S.B., Manual on the Hydraulic for Pumping Water, Intermediate technology publication, London, 1975. 70
Docsity logo


Copyright © 2024 Ladybird Srl - Via Leonardo da Vinci 16, 10126, Torino, Italy - VAT 10816460017 - All rights reserved